Plan Review Notes
Plan Review Notes For Permit 17051024
Permit Number 17051024
Review Stop R
Sequence Number 1
Notes
Date Text
2017-07-27 12:23:30ROOF PLAN REVIEW
 W. P. B. REVISION: 17051024
 W. P. B. PERMIT: 15110783
 ADD: 2915 S. DIXIE HWY.
 CONT: SUPERIOR CONCRETE, INC.
 TEL: 561-329-3575
 E-MAIL: [email protected]
  
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. JUNE 07/ 2017
 ACTION: PASSED
  
 MIAMIA-DADE NOA: 16-0413.06
 JOHNS MANVILLE APP MODIFIED BITUMEN ROOFING OVER WOOD
 DECK
 PAGE: 14
 MEMBRANE TYPE: APP
 DECK TYPE 1: WOOD / NON-INSULATED
 19/32 INCH GREATER PLYWOOD OR WOOD DECK
 SYSTEM TYPE E: BASE SHEET MECHANICALLY FASTENED
 MAXIMUM DESIGN PRESSURE -52.5 PSF GENERAL LIMITATION #
 7.
 BUNKER ENGINEERING/ ENHANCED FASTENING!!!