| Date |
Text |
| 2017-07-05 09:05:48 | PROVISOS |
| | ISSUED AT APPLICANT'S RISK |
| | |
| | 1) FBC BUILDING 1612 AND CITY OF WPB CODE OF ORDINANCES |
| | SECTION 94-546. STRUCTURE IS LOCATED IN AN "A" FLOOD |
| | ZONE. A FLOOD ELEVATION CERTIFICATE WILL BE REQUIRED. |
| | PLEASE REVIEW CITY ORDINANCE FOR THE CITY REQUIREMENTS |
| | REQUIRE AN ADDITIONAL 6 INCHES/ (12 INCHES OF ELEVATION |
| | IF PERMIT APPLICATION IS ON OR AFTER SEPT. 12/2016. |
| | |
| | DURING THE PERMITTING OF THIS STRUCTURE THERE WILL BE |
| | REQUIRED (3) DIFFERENT FLOOD ZONE CERTIFICATES |
| | REQUIRED: |
| | (1) A FLOOD ZONE CERTIFICATE IS REQUIRED AS PART OF THE |
| | PLAN REVIEW DOCUMENTS WITH THE PROPOSED FINISH FLOOR |
| | HEIGHT. |
| | |
| | (2) ONCE THE FIRST FLOOR SLAB IS POURED THE 2ND |
| | ELEVATION CERTIFICATE IS REQUIRED. |
| | |
| | (3) BEFORE THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY |
| | OR A CERTIFICATE OF COMPLETION THE 3RD FLOOD ZONE |
| | CERTIFICATE IS REQUIRED WITH THE HEIGHT OF ALL EXTERIOR |
| | ATTENDANTS A/C PADS OR OTHER SLABS FOR GENERATORS |
| | |
| | BATHROOMS/SHOWERS INSTALLATION SHALL COMPLY WITH |
| | |
| | FBC ACC 604.4 SEATS. |
| | THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH |
| | FLOOR SHALL BE 17 INCHES (430 MM) MINIMUM AND 19 INCHES |
| | (485 MM) MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS |
| | SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. |
| | |
| | THE COUNTERTOP FOR LAVATORY SHALL NOT EXTEND INTO THE |
| | CLEAR FLOOR SPACE OF THE WATER CLOSET. PER FBC ACC |
| | 604.3.1 SIZE. |
| | CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES |
| | (1525 MM) MINIMUM MEASURED PERPENDICULAR FROM THE SIDE |
| | WALL AND 56 INCHES (1420 MM) MINIMUM MEASURED |
| | PERPENDICULAR FROM THE REAR WALL. |
| | |
| | 604.3.2 OVERLAP. |
| | THE REQUIRED CLEARANCE AROUND THE WATER CLOSET SHALL BE |
| | PERMITTED TO OVERLAP THE WATER CLOSET, ASSOCIATED GRAB |
| | BARS, DISPENSERS, SANITARY NAPKIN DISPOSAL UNITS, COAT |
| | HOOKS, SHELVES, ACCESSIBLE ROUTES, CLEAR FLOOR SPACE |
| | AND CLEARANCES REQUIRED AT OTHER FIXTURES, AND THE |
| | TURNING SPACE. NO OTHER FIXTURES OR OBSTRUCTIONS SHALL |
| | BE LOCATED WITHIN THE REQUIRED WATER CLOSET CLEARANCE. |
| | |
| | FBC ACC 608.5.3 608.5.3 ALTERNATE ROLL-IN TYPE SHOWER |
| | COMPARTMENTS. |
| | IN ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENTS, THE |
| | CONTROLS, FAUCETS, AND SHOWER SPRAY UNIT SHALL BE |
| | LOCATED ABOVE THE GRAB BAR, BUT NO HIGHER THAN 48 |
| | INCHES (1220 MM) ABOVE THE SHOWER FLOOR. WHERE A SEAT |
| | IS PROVIDED, THE CONTROLS, FAUCETS, AND SHOWER SPRAY |
| | UNIT SHALL BE LOCATED ON THE SIDE WALL ADJACENT TO THE |
| | SEAT 27 INCHES (685 MM) MAXIMUM FROM THE SIDE WALL |
| | BEHIND THE SEAT OR SHALL BE LOCATED ON THE BACK WALL |
| | OPPOSITE THE SEAT 15 INCHES (380 MM) MAXIMUM, LEFT OR |
| | RIGHT, OF THE CENTERLINE OF THE SEAT. WHERE A SEAT IS |
| | NOT PROVIDED, THE CONTROLS, FAUCETS, AND SHOWER SPRAY |
| | UNIT SHALL BE INSTALLED ON THE SIDE WALL FARTHEST FROM |
| | THE COMPARTMENT ENTRY. |
| | |
| | FBC ACC 608.2.3 |
| | 608.2.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENTS. |
| | ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENTS SHALL BE 36 |
| | INCHES (915 MM) WIDE AND 60 INCHES (1525 MM) DEEP |
| | MINIMUM CLEAR INSIDE DIMENSIONS MEASURED AT CENTER |
| | POINTS OF OPPOSING SIDES. A 36 INCH (915 MM) WIDE |
| | MINIMUM ENTRY SHALL BE PROVIDED AT ONE END OF THE LONG |
| | SIDE OF THE COMPARTMENT. |
| | |
| | FBC ACC 610.3 AND 610.3.1 610.3 SHOWER COMPARTMENT |
| | SEATS. |
| | WHERE A SEAT IS PROVIDED IN A STANDARD ROLL-IN SHOWER |
| | COMPARTMENT, IT SHALL BE A FOLDING TYPE, SHALL BE |
| | INSTALLED ON THE SIDE WALL ADJACENT TO THE CONTROLS, |
| | AND SHALL EXTEND FROM THE BACK WALL TO A POINT WITHIN 3 |
| | INCHES (75 MM) OF THE COMPARTMENT ENTRY. WHERE A SEAT |
| | IS PROVIDED IN AN ALTERNATE ROLL-IN TYPE SHOWER |
| | COMPARTMENT, IT SHALL BE A FOLDING TYPE, SHALL BE |
| | INSTALLED ON THE FRONT WALL OPPOSITE THE BACK WALL, AND |
| | SHALL EXTEND FROM THE ADJACENT SIDE WALL TO A POINT |
| | WITHIN 3 INCHES (75 MM) OF THE COMPARTMENT ENTRY. IN |
| | TRANSFER-TYPE SHOWERS, THE SEAT SHALL EXTEND FROM THE |
| | BACK WALL TO A POINT WITHIN 3 INCHES (75 MM) OF THE |
| | COMPARTMENT ENTRY. THE TOP OF THE SEAT SHALL BE 17 |
| | INCHES (430 MM) MINIMUM AND 19 INCHES (485 MM) MAXIMUM |
| | ABOVE THE BATHROOM FINISH FLOOR. SEATS SHALL COMPLY |
| | WITH 610.3.1 OR 610.3.2. |
| | 610.3.1 RECTANGULAR SEATS. |
| | THE REAR EDGE OF A RECTANGULAR SEAT SHALL BE 2 1/2 |
| | INCHES (64 MM) MAXIMUM AND THE FRONT EDGE 15 INCHES |
| | (380 MM) MINIMUM AND 16 INCHES (405 MM) MAXIMUM FROM |
| | THE SEAT WALL. THE SIDE EDGE OF THE SEAT SHALL BE 11/2 |
| | INCHES (38 MM) MAXIMUM FROM THE ADJACENT WALL. |
| | |