| Date |
Text |
| 2017-05-11 08:54:14 | 2014 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 17050465 |
| | ADD: 301 BAKER DR. |
| | CONT: O/B JAMES M. TRESSICA |
| | TEL: 561-856-1267 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: |
| | ACTION: BUILDING PROVISOROOFING ASPHALT SHINGLES 2014< |
| | 4/12 PITCH. |
| | R905.2.7 UNDERLAYMENT APPLICATION. |
| | |
| | 1) FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS |
| | HORIZONTAL (17-PERCENT SLOPE), AND LESS THAN FOUR UNITS |
| | VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE). |
| | UNDERLAYMENT SHALL COMPLY WITH ASTM D 226, TYPE I |
| | OR TYPE II OR ASTM D 4869, TYPE II OR TYPE IV OR ASTM D |
| | 6757 AND SHALL BE TWO LAYERS APPLIED IN THE FOLLOWING |
| | MANNER. APPLY A 19-INCH (483 MM) STRIP OF UNDERLAYMENT |
| | FELT PARALLEL TO AND STARTING AT THE EAVES, FASTENED |
| | SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE, |
| | APPLY |
| | 36-INCH-WIDE (914 MM) SHEETS OF UNDERLAYMENT, |
| | OVERLAPPING SUCCESSIVE SHEETS 19 INCHES. |
| | |
| | JAMES A. WITMER BN, PX, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | 401 CLEMATIS ST. |
| | WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |