| Notes |
| Date |
Text |
| 2017-05-12 11:28:59 | PASSED WITH PROVISO: | | | | | | 1. DUMPSTER PAD NEED TO BE EXTENDED OUT EXTRA 10' | | | BEYOND THE ENCLOSURE GATE WHERE THE DOUBLE GATES OPEN | | | (SHALL BE 6-INCH IN THICKNESS, SIMILAR TO THE ENCLOSURE | | | PAD), ASPHALT APRON WILL NOT BE ADEQUATE TO WITHOLD THE | | | LOADING FROM DUMP TRUCK WEIGHT; | | | | | | 2. NO DIMENSION IS GIVEN TO SHOW HOW FAR IS THE | | | LOCATION OF THE PROPOSED DUMPSTER ENCLOSURE FROM THE | | | SOUTH WALL. THERE IS OVERHEAD CABLES RUNNING BETWEEN | | | POLES IN THE AREA ALONG THE SOUTH WALL. GARBAGE | | | COLLECTION OPERATION BY DUMPSTER TRUCKS NEED VERTICAL | | | CLEARANCE AND ENCLOSURE LOCATION NEED TO BE IN A CLEAR | | | ZONE AWAY FROM THE OVERHEAD CABLES/POLES/GUY WIRES ETC. | | | |
|