Plan Review Notes
Plan Review Notes For Permit 17050311
Permit Number 17050311
Review Stop B
Sequence Number 1
Notes
Date Text
2017-05-16 09:31:34BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND
 THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON
 RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE.
  
 1. PROVIDE SITE PLAN IDENTIFYING LOCATION OF PROPOSED
 RAMP.
 2. PROVIDE PLAN OF RAMP CONSTRUCTION.
  
 FBC 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS
 SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE
 ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE
 AND LOCATION OF NEW CONSTRUCTION AND EXISTING
 STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE
 ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED
 GRADES AND, AS APPLICABLE, FLOOD HAZARD AREAS,
 FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT SHALL BE
 DRAWN IN ACCORDANCE WITH AN ACCURATE BOUNDARY LINE
 SURVEY.
 IN THE CASE OF DEMOLITION, THE SITE PLAN SHALL SHOW
 CONSTRUCTION TO BE DEMOLISHED AND THE LOCATION AND SIZE
 OF EXISTING STRUCTURES AND CONSTRUCTION THAT ARE TO
 REMAIN ON THE SITE OR PLOT. THE BUILDING OFFICIAL IS
 AUTHORIZED TO WAIVE OR MODIFY THE REQUIREMENT FOR A
 SITE PLAN WHEN THE APPLICATION FOR PERMIT IS FOR
 ALTERATION OR REPAIR OR WHEN OTHERWISE WARRANTED.
  
 R311.8 RAMPS.
  
 R311.8.1 MAXIMUM SLOPE.
 RAMPS SHALL HAVE A MAXIMUM SLOPE OF 1 UNIT VERTICAL IN
 12 UNITS HORIZONTAL (8.3-PERCENT SLOPE).
  
 EXCEPTION: WHERE IT IS TECHNICALLY INFEASIBLE TO COMPLY
 BECAUSE OF SITE CONSTRAINTS, RAMPS MAY HAVE A MAXIMUM
 SLOPE OF ONE UNIT VERTICAL IN EIGHT HORIZONTAL
 (12.5-PERCENT SLOPE).
  
 R311.8.2 LANDINGS REQUIRED.
 A MINIMUM 3-FOOT-BY-3-FOOT (914 MM BY 914 MM) LANDING
 SHALL BE PROVIDED:
 1. AT THE TOP AND BOTTOM OF RAMPS.
 2. WHERE DOORS OPEN ONTO RAMPS.
 3. WHERE RAMPS CHANGE DIRECTION.
  
 R311.8.3 HANDRAILS REQUIRED.
 HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF ALL
 RAMPS EXCEEDING A SLOPE OF ONE UNIT VERTICAL IN 12
 UNITS HORIZONTAL (8.33-PERCENT SLOPE).
  
 R311.8.3.1 HEIGHT.
 HANDRAIL HEIGHT, MEASURED ABOVE THE FINISHED SURFACE OF
 THE RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES (864
 MM) AND NOT MORE THAN 38 INCHES (965 MM).
  
 R311.8.3.2 GRIP SIZE.
 HANDRAILS ON RAMPS SHALL COMPLY WITH SECTION
 R311.7.8.3.
  
 R311.8.3.3 CONTINUITY.
 HANDRAILS WHERE REQUIRED ON RAMPS SHALL BE CONTINUOUS
 FOR THE FULL LENGTH OF THE RAMP. HANDRAIL ENDS SHALL BE
 RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR SAFETY
 TERMINALS. HANDRAILS ADJACENT TO A WALL SHALL HAVE A
 SPACE OF NOT LESS THAN 11/2 INCHES (38 MM) BETWEEN THE
 WALL AND THE HANDRAILS.
  
 SECTION R312 GUARDS AND WINDOW FALL PROTECTION
  
 R312.1 GUARDS.
 GUARDS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS
 R312.1.1 THROUGH R312.1.4.
  
 R312.1.1 WHERE REQUIRED.
 GUARDS SHALL BE LOCATED ALONG OPEN-SIDED WALKING
 SURFACES, INCLUDING STAIRS, RAMPS AND LANDINGS, THAT
 ARE LOCATED MORE THAN 30 INCHES (762 MM) MEASURED
 VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT
 WITHIN 36 INCHES (914 MM) HORIZONTALLY TO THE EDGE OF
 THE OPEN SIDE. INSECT SCREENING SHALL NOT BE CONSIDERED
 AS A GUARD.
  
 R312.1.2 HEIGHT.
 REQUIRED GUARDS AT OPEN-SIDED WALKING SURFACES,
 INCLUDING STAIRS, PORCHES, BALCONIES OR LANDINGS, SHALL
 BE NOT LESS THAN 36 INCHES (914 MM) HIGH MEASURED
 VERTICALLY ABOVE THE ADJACENT WALKING SURFACE, ADJACENT
 FIXED SEATING OR THE LINE CONNECTING THE LEADING EDGES
 OF THE TREADS.
  
 EXCEPTIONS:
  
 1. GUARDS ON THE OPEN SIDES OF STAIRS SHALL HAVE A
 HEIGHT NOT LESS THAN 34 INCHES (864 MM) MEASURED
 VERTICALLY FROM A LINE CONNECTING THE LEADING EDGES OF
 THE TREADS.
 2. WHERE THE TOP OF THE GUARD ALSO SERVES AS A HANDRAIL
 ON THE OPEN SIDES OF STAIRS, THE TOP OF THE GUARD SHALL
 NOT BE LESS THAN 34 INCHES (864 MM) AND NOT MORE THAN
 38 INCHES (965 MM) MEASURED VERTICALLY FROM A LINE
 CONNECTING THE LEADING EDGES OF THE TREADS.
  
 R312.1.3 OPENING LIMITATIONS.
 REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE
 WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH
 ALLOW PASSAGE OF A SPHERE 4 INCHES (102 MM) IN
 DIAMETER.
  
 EXCEPTIONS:
  
 1. THE TRIANGULAR OPENINGS AT THE OPEN SIDE OF STAIR,
 FORMED BY THE RISER, TREAD AND BOTTOM RAIL OF A GUARD,
 SHALL NOT ALLOW PASSAGE OF A SPHERE 6 INCHES (153 MM)
 IN DIAMETER.
 2. GUARDS ON THE OPEN SIDE OF STAIRS SHALL NOT HAVE
 OPENINGS WHICH ALLOW PASSAGE OF A SPHERE 43/8 INCHES
 (111 MM) IN DIAMETER.
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved