| Date |
Text |
| 2017-05-12 09:49:58 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6724 |
| | |
| | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) |
| | FBC B = FBC BUILDING |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | |
| | 1. FBC B 1609, FBC 107, ANCHORS REQUIRED OR |
| | CONFIGURATION IS NOT CLEAR. |
| | |
| | WALL CABINET SIGN - PLAN STATES "MIN NUMBER OF TOP OR |
| | BOTTOM ANCHORS = 4 NO." WITHOUT SPECIFYING LOCATIONS. |
| | THE PLAN GRAPHICALLY DEPICTS SIX ANCHORS. ARE SIX |
| | REQUIRED, OR FOUR REQUIRED AND SIX PROPOSED? THE SIGN |
| | IS 18' LONG. |
| | |
| | CHANNEL LETTER SIGN CALCS STATE 2 TOP OR BOTTOM ARE OK. |
| | THE LETTER "L" IS SHOWN WITH ONLY ONE FASTENER, REVISE. |
| | THE LETTER E (THREE LOCATIONS) IS SHOWN WITH TWO TOP |
| | AND BOTTOM, NONE ON THE CANTILEVERED PORTION IN THE |
| | MIDDLE; IS THIS ENGINEER'S INTENT? REVISE PLAN TO |
| | CLARIFY PROPOSED INSTALLATION. |
| | |
| | 2. FBC 107, FBC B 1609, THE ENGINEERING SHOWS TWO SIGNS |
| | (ONE VERTICAL, ONE HORIZONTAL). THE UNSEALED PLAN SHOWS |
| | AN ADDITIONAL ADDRESS PIN MOUNT ADDRESS SIGN. |
| | |
| | THIS PERMIT WILL BE ISSUED WITH PROVISO: ADDRESS SIGN |
| | SHALL COMPLY WITH FBC B 501.2; CONFIRM LOCATION WITH |
| | FIRE. |
| | |
| | 3. THE MAJORITY OF THE APPLICATION IS BLANK. PLEASE |
| | PROVIDE CONTACT INFORMATION ON THIS TBD APPLICATION AS |
| | THIS MAY BE IMPORTANT AT SOME POINT FOR PLAN REVIEWERS |
| | TO HAVE THE OPTION OF CONTACTING THE APPLICANT (PROVISO |
| | RATHER THAN FAIL A PLAN REVIEW). |
| | |
| | |
| | |