| Date |
Text |
| 2017-05-26 16:59:57 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS. |
| | CODE: FBC 5TH EDITION (2014). |
| | |
| | 1- VALUATION DECLARED IN THE PERMIT APPLICATION IS |
| | EXTREMELY LOW. VALUATION TO INCLUDE ALL THE SCOPE SCOPE |
| | OF WORK INCLUDING LABOR, MATERIALS, CONTRACTOR'S |
| | OVERHEAD AND PROFIT AND ALL DESIGN PROFESSIONAL FEES AS |
| | REQUIRED BY SEC. 109.3 CITY AMENDMENTS. VALUATION WAS |
| | UPDATED TO +/- $40,000. THE PERMIT FEE BALANCE IS |
| | $2578.68. |
| | |
| | 2- THIS PROPERTY IS LOCATED IN FLOOD ZONE A5. BASED ON |
| | THE VALUE OF THE BUILDING ALONE, ACCORDING TO THE PALM |
| | BEACH COUNTY PROPERTY APPRAISER, IT LOOKS LIKE THE |
| | PROPOSED SCOPE OF WORK AND WORK PERFORMED IN THE PAST |
| | WILL TRIGGER THE SUBSTANTIAL IMPROVEMENT REQUIREMENTS |
| | OF THE CITY OF WEST PALM BEACH FLOODPLAIN MANAGEMENT |
| | POLICY. PLEASE PROVIDE COPY OF THE SURVEY (2 COPIES) |
| | SHOWING THE EXISTING FINISH FLOOR ELEVATION OF THE |
| | HOUSE TO VERIFY IF THE HOUSE COMPLIES WITH THE MINIMUM |
| | FINISH FLOOR ELEVATION REQUIRED. SEC. 94- 541 CITY |
| | CODE. |
| | NOTE: ELEVATION CERTIFICATE IS REQUIRED FOR PROPERTIES |
| | LOCATED IN THE FLOOD ZONE. |
| | |
| | 3- SHEET A-3: |
| | A) PLANS NEED TO SPECIFY THE DESIGN CRITERIA INCLUDING |
| | THE CURRENT CODE, WIND LOADS (ULTIMATE AND NOMINAL), |
| | BUILDING EXPOSURE, ETC. AS REQUIRED BY CHAPTER 553 |
| | FLORIDA STATUTES AND SEC. R301.1 FBC-RESIDENTIAL, 5TH |
| | EDITION (2014). |
| | |
| | B) THE EXISTING DEN SHOWN ON THE EXISTING FLOOR PLAN IS |
| | CONVERTED INTO A BEDROOM. REVISE THE NAME OF ROOM ON |
| | THE "AS BUILT FLOOR PLAN" AND "ELECTRICAL FLOOR PLAN". |
| | SPECIFY BEDROOM. SEC. 102.2 AND 107.2.1 CITY |
| | AMENDMENTS. |
| | |
| | C) SCALE SPECIFIED ON THE FLOOR PANS ON SHEET A-3 IS |
| | INCORRECT. REVISE AS REQUIRED. SEC. 107.2.1 CITY |
| | AMENDMENTS. |
| | |
| | |
| | NOTE: |
| | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| | ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS |
| | FOR REFERENCE. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |
| | |