Plan Review Notes For Permit 17041227
Permit Number 17041227
Review Stop Z
Sequence Number 1
Notes
Date Text
2017-05-25 15:09:39**********************************ZONING
 REVIEW***********************************
  
 DEVELOPMENT STANDARDS IN THE INDUSTRIAL (I) DISTRICT
 SHALL BE AS FOLLOWS:
  
 (1) MINIMUM LOT DIMENSIONS:
 A. LOT AREA: 5,000 SQUARE FEET.
 B. LOT WIDTH: 50 FEET.
  
 (2) MINIMUM SETBACKS:
 A. MINIMUM SETBACK FROM PROPERTY LINE ADJOINING PUBLIC
 RIGHT-OF-WAY: ZERO FEET.
 B. MINIMUM SETBACK FROM PROPERTY LINE NOT ADJOINING
 PUBLIC RIGHT-OF-WAY: ZERO FEET; HOWEVER, A MINIMUM
 SETBACK OF AT LEAST 15 FEET (BUFFER) WILL BE PROVIDED
 WHEN ABUTTING RESIDENTIAL DISTRICTS.
  
 (3) MAXIMUM LOT COVERAGE BY BUILDING: 60 PERCENT.
  
 (4) MAXIMUM LOT COVERAGE BY IMPERVIOUS SURFACE: 85
 PERCENT.
  
 (5) MAXIMUM BUILDING HEIGHT: 50 FEET.
  
 (6) MINIMUM REQUIRED OPEN SPACE AND LANDSCAPE AREAS:
 A. MINIMUM REQUIRED OPEN SPACE AREA: 40 PERCENT.
 B. MINIMUM REQUIRED LANDSCAPE AREA: 15 PERCENT.
  
 (7) MAXIMUM FLOOR AREA RATIO:
 A. 0.75
 B. PLANNED DEVELOPMENT: 0.75
  
 PLEASE MAKE SURE THAT YOU INCLUDE ALL OF THE
 DEVELOPMENT STANDARDS IN PROJECT DATA TABLE FOR THIS
 LOT TO ENSURE THAT YOU ARE MEETING THE REQUIREMENTS
 (OPEN SPACE AND LANDSCAPE AREA PERCENTAGES ARE
 MISSING). PLEASE LET ME KNOW WHAT QUESTIONS YOU MAY
 HAVE.
  