| 2017-05-23 14:43:35 | 2014 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 17041227 |
| | ADD: 5015 GEORGIA AVE. |
| | CONT: GRUBER HALL CORP. |
| | TEL: 561-662-3377 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: TUES. MAY 23, 2017 |
| | ACTION: DENIED |
| | |
| | 1) COVERSHEET C1 INDICATES THE 2014 FLORIDA BUILDING |
| | CODE DESIGN DATA; |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR |
| | BUILDINGS. |
| | 107.3.5.1 COMMERCIAL BUILDINGS: |
| | 107.3.5.1.1 BUILDING |
| | 1A) MINIMUM TYPE OF CONSTRUCTION FBC-B TABLE 503. |
| | |
| | 1B) THE PLANS INDICATE AN R3 OCCUPANCY. PLEASE CORRECT. |
| | PLEASE PROVIDE OCCUPANCY TYPES. THIS APPEARS TO BE A |
| | MIXED USE OCCUPANCY BUSINESS AND STORAGE, PLEASE |
| | INDICATE IF THE STORAGE IS S1 OR S2. 107.2.1.3 |
| | ADDITIONAL INFORMATION REQUIRED. |
| | |
| | 1C) PLANS DO NOT INDICATE IF THE BUILDING IS FIRE |
| | SPRINKLERED OR NOT? 107.3.5.1 COMMERCIAL BUILDINGS(5). |
| | |
| | 1D) PLANS ARE SILENT AS TO THE DESIGN, IF THE DIFFERENT |
| | OCCUPANCIES ARE TO BE SEPARATED (FBC-B 508.2.4) OR |
| | NON-SEPARATED (FBC-B 508.3) OCCUPANCIES? |
| | |
| | 1E) THE COVERSHEET INDICATES THE MEAN ROOF HEIGHT OF 15 |
| | FEET WHEREAS SHEET S2.0 PROVIDES A MEAN ROOF HEIGHT OF |
| | 22.5 FEET. PLEASE CORRECT THE DISCREPANCY IN PLANS. |
| | 107.2.1.3 ADDITIONAL INFORMATION REQUIRED. |
| | |
| | 1F) SHEET SP1 INDICATES THE SIDE ROAD ADJACENT TO THIS |
| | LOT IS EAGLES NEST RD. WHEREAS THE COUNTYWIDE GIS AND |
| | P. B. C. PROPERTY APPRAISERS OFFICE BOTH SHOW THE SIDE |
| | ROAD TO BE MCINTOSH ST. 107.2.1.3 ADDITIONAL |
| | INFORMATION REQUIRED. |
| | |
| | 2) MISSING SOILS REPORTS? 2014 FBC-B 1803.5.2 |
| | QUESTIONABLE SOIL. SUBMIT (2) SIGNED AND SEALED |
| | ORIGINAL SOILS REPORTS. |
| | |
| | 3) SUBMIT ENERGY CALCULATIONS FOR THE ADDITION. SEE |
| | 2014 FBC-ENERGY C101.4.3. |
| | |
| | 4) SHEET A1 INDICATES THE COMPONENTS AND CLADDING |
| | PRESSURES, THE PRESSURES ARE LEFT BLANK. SHEET S2.0 |
| | ALSO INDICATES THE WIND DESIGN PRESSURES. THE PRESSURES |
| | ALSO INDICATE THIS IS A R3 OCCUPANCY. THE WIND DESIGN |
| | INDICATES VULT AND VASD AS PART OF THE WIND DESIGN. THE |
| | PLANS INDICATE THAT THE PRESSURES ARE MAXIMUM DOOR AND |
| | WINDOW PRESSURES : |
| | WINDOW +45.7 -61.6 |
| | DOOR +44.5 -57.6 |
| | |
| | IF PRESSURES ARE VULT/ EXPOSURE C/ 10 SQ. FT. WALL ZONE |
| | 5 / 22.5 MRH / +69.42/ -92.9 |
| | IF PRESSURES ARE VASD/ EXPOSURE C/ 10 SQ. FT. WALL ZONE |
| | 5/ 22.5 MRH / +41.64/ -55.71 |
| | |
| | 5) SHEET A3.0 INDICATES THE USE OF 2 X 12 ROOF FRAMING |
| | MEMBERS. PLEASE IDENTIFY THE SPECIES OF WOOD AND GRADE |
| | OF WOOD. PROVIDE THE LIVE LOADS CEILING ATTACHED AND |
| | ALLOWABLE DEFLECTION. SEE FBC-B TABLE 2308.10.3 RAFTER |
| | SPANS. |
| | |
| | 6) SHEET A3.0 ALSO INDICATES THE USE OF ICYNENE |
| | INSULATION IN THE RAFTERS, PLEASE PROVIDE THE |
| | MANUFACTURERS INSTALLATION REPORT, (ICC-ES REPORT). |
| | |
| | 7) SHEET A3.0 INDICATES THE USE OF CEILING JOIST FOR ? |
| | OF THE CEILING FRAMING. THE PLANS DO NOT PROVIDE A |
| | DETAIL OF HOW THE CEILING JOISTS ARE TO ATTACHED TO THE |
| | CMU BLOCK WALL? NOR HOW THE CEILING JOIST IS TO BE |
| | ANCHORED TO THE 2 X12 RAFTERS? 107.2.1.3 ADDITIONAL |
| | INFORMATION. |
| | |
| | 8) IMPACT FEES |
| | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER BN, PX, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | 401 CLEMATIS ST. |
| | WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |