| Plan Review Notes For Permit 17041203 |
| Permit Number |
17041203 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2017-05-02 18:09:30 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE WATER CLOSETS IN THE WOMENS BATHROOM AND IN | | | PRIVATE OFFICE BATHROOM ARE NOT VENTED IF THEY ARE | | | CONNECTED TO THE BUILDING DRAIN THEY WILL NEED TO BE | | | INDIVIDUALLY VENTED. PER FBC PL 901.2.1 | | | | | | 2. THE LAVATORY'S IN THE BATHROOMS SHALL BE SUPPLIED | | | WITH TEMPERED WATER . PER FBC PL 416.5 | | | | | | 3. PLEASE SHOW KNEE AND TOE CLEARANCE FOR THE | | | LAVATORY'S. PER FBC ACC 606.2 | | | | | | 4. GRAB BARS SHALL BE MEASURED FROM THE TOP OF THE | | | GRIPPING SURFACE TO THE FINISHED FLOOR. FBC ACC 609.4 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|