2017-04-19 13:57:092014 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17040694
 ADD: 3000 N. AUSTRALIAN AVE.
 CONT: DOSDOURIAN ENTERPRISES
 TEL: 561-844-2990
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. APRIL 19, 2017
 ACTION: DENIED
  
 1A) SHEET G003 THE LIFE SAFETY PLAN INDICATES THIS IS
 AN A3 OCCUPANCY, BUILDING TYPE III-B/ NON-SPRINKLERED,
 BUILDING, WITH AN OCCUPANT LOAD OF 278. THE PLANS FAILS
 TO SHOW FIRE RATED CORRIDORS 101, 105 & 116 ( 2014
 FBC-B TABLE 1018.1)WITH OPENING PROTECTIVES (DOOR &
 WINDOWS) IN ACCORDANCE WITH TABLE 716.5.
  
 1B) THE MECHANICAL DUCTS THAT PENETRATE THE CORRIDOR
 WALLS LISTED ABOVE IN COMMENT 1A WILL NEED TO SHOW
 COMPLIANCE WITH FBC-B DUCTS AND AIR TRANSFER OPENINGS ,
 PENETRATIONS THROUGH FIRE RATED WALLS.
  
 1C) ROOM 111 THE MAIN AUDITORIUM THE BACK ROW IS
 PARTIALLY BLOCKED, THE AISLE ACCESSWAY IS PARTIALLY
 BLOCKED BY THE END SEAT IN THE NEXT FORWARD ROW AT EACH
 END OF THE ROW. PLEASE REVIEW FBC-B 1028.9.1. EXCEPTION
 3 (2). THIRTY INCHES WHERE THE AISLE DOES NOT SERVES
 MORE THAN 14 SEATS.
  
 1D) ROOM 111 THE MAIN AUDITORIUM THE 4TH ROW FROM THE
 FRONT PLEASE DIMENSION THE CLEAR WITH OF THE AISLES, IT
 APPEARS THEY MAY NOT CONFORM TO: 2014 FBC-B 1028.9.1(4)
 FORTY-TWO INCHES (1067 MM) FOR LEVEL OR RAMPED AISLES
 HAVING SEATING ON BOTH SIDES.
  
 1E) SHEET G003 THE BOTTOM LEFT CORNER OF THE SHEET
 INDICATES IN A NOTE ROOMS 111 & 112 TO BE FIRE RATED,
 NOT LOCATED IN THE FLOOR PLAN? 107.2.1.3 ADDITIONAL
 INFORMATION IS REQUIRED?
  
 2) SHEET A103 THE ROOF PLAN, SHEET KEY NOTES:
 2A) A197 REPAIR ROTTING TRUSSES. IS THERE A STRUCTURAL
 ENGINEER WHO WILL BE PROVIDING DETAILS ON HOW THE
 ROTTING TRUSSES ARE GOING TO BE REPAIRED? 107.2.1.3
 ADDITIONAL INFORMATION IS REQUIRED.
  
 2B) NOTE IN THE ROOF PLAN ITSELF, CONTRACTOR TO VERIFY
 ALL ROOF VENTS ARE CLOSED IN THE MAIN BUILDING ROOF?
 PLEASE PROVIDE HOW COMPLIANCE WITH FBC-B 1203.2 (1-3)
 IS GOING TO BE MET.
  
 2C) NOTE A198 IS RIDGE VENT IS FOR PORTICO ONLY. NO
 PRODUCT APPROVALS WERE SUBMITTED FOR THIS APPLICATION.
 COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY
 AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3
 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31(D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP
 VENTILATORS
 2D) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 3) PERMIT APPLICATION 17040695 LICENSE # CCC056366/
 FL00914 A ROOFING LICENSE IS WORKING OUT OF THE SCOPE
 OF THEIR LICENSE. REMOVE AND REPLACE EXISTING FINISHES
 AND BATHROOMS. I BELIEVE THIS IS A TYPO AND NEEDS TO BE
 CORRECTED. PLEASE PROVIDE THE AREAS OF THE ROOF THAT
 ARE TO BE REROOFED? PROVIDE THE SQUARE FOOTAGE OF
 ROOFING TO BE REPLACED. 107.2.1.3 ADDITIONAL
 INFORMATION IS REQUIRED.
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved