| Date |
Text |
| 2017-04-19 13:57:09 | 2014 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 17040694 |
| | ADD: 3000 N. AUSTRALIAN AVE. |
| | CONT: DOSDOURIAN ENTERPRISES |
| | TEL: 561-844-2990 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: WED. APRIL 19, 2017 |
| | ACTION: DENIED |
| | |
| | 1A) SHEET G003 THE LIFE SAFETY PLAN INDICATES THIS IS |
| | AN A3 OCCUPANCY, BUILDING TYPE III-B/ NON-SPRINKLERED, |
| | BUILDING, WITH AN OCCUPANT LOAD OF 278. THE PLANS FAILS |
| | TO SHOW FIRE RATED CORRIDORS 101, 105 & 116 ( 2014 |
| | FBC-B TABLE 1018.1)WITH OPENING PROTECTIVES (DOOR & |
| | WINDOWS) IN ACCORDANCE WITH TABLE 716.5. |
| | |
| | 1B) THE MECHANICAL DUCTS THAT PENETRATE THE CORRIDOR |
| | WALLS LISTED ABOVE IN COMMENT 1A WILL NEED TO SHOW |
| | COMPLIANCE WITH FBC-B DUCTS AND AIR TRANSFER OPENINGS , |
| | PENETRATIONS THROUGH FIRE RATED WALLS. |
| | |
| | 1C) ROOM 111 THE MAIN AUDITORIUM THE BACK ROW IS |
| | PARTIALLY BLOCKED, THE AISLE ACCESSWAY IS PARTIALLY |
| | BLOCKED BY THE END SEAT IN THE NEXT FORWARD ROW AT EACH |
| | END OF THE ROW. PLEASE REVIEW FBC-B 1028.9.1. EXCEPTION |
| | 3 (2). THIRTY INCHES WHERE THE AISLE DOES NOT SERVES |
| | MORE THAN 14 SEATS. |
| | |
| | 1D) ROOM 111 THE MAIN AUDITORIUM THE 4TH ROW FROM THE |
| | FRONT PLEASE DIMENSION THE CLEAR WITH OF THE AISLES, IT |
| | APPEARS THEY MAY NOT CONFORM TO: 2014 FBC-B 1028.9.1(4) |
| | FORTY-TWO INCHES (1067 MM) FOR LEVEL OR RAMPED AISLES |
| | HAVING SEATING ON BOTH SIDES. |
| | |
| | 1E) SHEET G003 THE BOTTOM LEFT CORNER OF THE SHEET |
| | INDICATES IN A NOTE ROOMS 111 & 112 TO BE FIRE RATED, |
| | NOT LOCATED IN THE FLOOR PLAN? 107.2.1.3 ADDITIONAL |
| | INFORMATION IS REQUIRED? |
| | |
| | 2) SHEET A103 THE ROOF PLAN, SHEET KEY NOTES: |
| | 2A) A197 REPAIR ROTTING TRUSSES. IS THERE A STRUCTURAL |
| | ENGINEER WHO WILL BE PROVIDING DETAILS ON HOW THE |
| | ROTTING TRUSSES ARE GOING TO BE REPAIRED? 107.2.1.3 |
| | ADDITIONAL INFORMATION IS REQUIRED. |
| | |
| | 2B) NOTE IN THE ROOF PLAN ITSELF, CONTRACTOR TO VERIFY |
| | ALL ROOF VENTS ARE CLOSED IN THE MAIN BUILDING ROOF? |
| | PLEASE PROVIDE HOW COMPLIANCE WITH FBC-B 1203.2 (1-3) |
| | IS GOING TO BE MET. |
| | |
| | 2C) NOTE A198 IS RIDGE VENT IS FOR PORTICO ONLY. NO |
| | PRODUCT APPROVALS WERE SUBMITTED FOR THIS APPLICATION. |
| | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY |
| | AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 |
| | NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR |
| | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT |
| | APPROVALS: |
| | (31(D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP |
| | VENTILATORS |
| | 2D) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 3) PERMIT APPLICATION 17040695 LICENSE # CCC056366/ |
| | FL00914 A ROOFING LICENSE IS WORKING OUT OF THE SCOPE |
| | OF THEIR LICENSE. REMOVE AND REPLACE EXISTING FINISHES |
| | AND BATHROOMS. I BELIEVE THIS IS A TYPO AND NEEDS TO BE |
| | CORRECTED. PLEASE PROVIDE THE AREAS OF THE ROOF THAT |
| | ARE TO BE REROOFED? PROVIDE THE SQUARE FOOTAGE OF |
| | ROOFING TO BE REPLACED. 107.2.1.3 ADDITIONAL |
| | INFORMATION IS REQUIRED. |
| | |
| | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER BN, PX, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | 401 CLEMATIS ST. |
| | WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |