2017-04-28 07:43:36BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
  
 DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND
 THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON
 RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE.
  
 1. SITE PLAN PROVIDED SHOWS ONLY EXISTING STRUCTURES.
 IDENTIFY ALL PROPOSED WORK.
 2. CARPORT INSTALLATION INSTRUCTIONS TO BE REVIEWED AND
 APPROVED BY DESIGNER.
 3. IDENTIFY TYPE OF FOUNDATION ANCHORAGE.
 4. PROVIDE DETAIL OF FOUNDATION.
 5. R301.1.3 ENGINEERED DESIGN.
 WHEN A BUILDING OF OTHERWISE CONVENTIONAL CONSTRUCTION
 CONTAINS STRUCTURAL ELEMENTS EXCEEDING THE LIMITS OF
 SECTION R301 OR OTHERWISE NOT CONFORMING TO THIS CODE,
 THESE ELEMENTS SHALL BE DESIGNED IN ACCORDANCE WITH
 ACCEPTED ENGINEERING PRACTICE. THE EXTENT OF SUCH
 DESIGN NEED ONLY DEMONSTRATE COMPLIANCE OF
 NONCONVENTIONAL ELEMENTS WITH OTHER APPLICABLE
 PROVISIONS AND SHALL BE COMPATIBLE WITH THE PERFORMANCE
 OF THE CONVENTIONAL FRAMED SYSTEM. ENGINEERED DESIGN IN
 ACCORDANCE WITH THE FLORIDA BUILDING CODE, BUILDING IS
 PERMITTED FOR ALL BUILDINGS AND STRUCTURES, AND PARTS
 THEREOF, INCLUDED IN THE SCOPE OF THIS CODE.
 6. FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
 R301.2.1 WIND DESIGN CRITERIA.
 BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN
 ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING
 THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED
 FROM FIGURE R301.2(4). THE STRUCTURAL PROVISIONS OF
 THIS CODE FOR WIND LOADS ARE NOT PERMITTED WHERE WIND
 DESIGN IS REQUIRED AS SPECIFIED IN SECTION R301.2.1.1.
 WHERE DIFFERENT CONSTRUCTION METHODS AND STRUCTURAL
 MATERIALS ARE USED FOR VARIOUS PORTIONS OF A BUILDING,
 THE APPLICABLE REQUIREMENTS OF THIS SECTION FOR EACH
 PORTION SHALL APPLY. WHERE NOT OTHERWISE SPECIFIED, THE
 WIND LOADS LISTED IN TABLE R301.2(2) ADJUSTED FOR
 HEIGHT AND EXPOSURE USING TABLE R301.2(3) SHALL BE USED
 TO DETERMINE DESIGN LOAD PERFORMANCE REQUIREMENTS FOR
 WALL COVERINGS, CURTAIN WALLS, ROOF COVERINGS, EXTERIOR
 WINDOWS, SKYLIGHTS AND EXTERIOR DOORS (OTHER THAN
 GARAGE DOORS).
 7. THE PERMIT VALUATION AND PERMIT FEE MUST BE
 COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED
 CONTRACTOR WOULD PROVIDE.
 YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE
 OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT
 RENTAL TO VERIFY VALUE.
  
  