| Plan Review Notes For Permit 17040422 |
| Permit Number |
17040422 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2017-04-13 09:33:48 | BUILDING PROVISO: | | | 4/13/2017 2014 FBC-B 2509.2 BASE FOR TILE. | | | WATER-RESISTANT GYPSUM BACKING BOARD SHALL NOT BE USED | | | AS A BASE FOR TILE IN SHOWER STALLS. | | | GLASS MAT WATER-RESISTANT GYPSUM BACKING PANELS, | | | DISCRETE NONASBESTOS FIBER-CEMENT INTERIOR SUBSTRATE | | | SHEETS OR NONASBESTOS FIBER-MAT | | | REINFORCED CEMENTITIOUS BACKER UNITS IN COMPLIANCE WITH | | | ASTM C 1178, C 1288 OR C 1325 AND INSTALLED IN | | | ACCORDANCE WITH MANUFACTURER | | | RECOMMENDATIONS SHALL BE USED AS A BASE FOR WALL TILE | | | IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN | | | SHOWER AREAS. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|