Plan Review Notes
Plan Review Notes For Permit 17040361
Permit Number 17040361
Review Stop E
Sequence Number 1
Notes
Date Text
2017-05-02 12:29:55JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 SERVICE MAINS TO BE GROUPED 230.72, FBCRE3601.7
  
 FBCRE3903.3 ADDITIONAL LOCATIONS.
 AT LEAST ONE WALL-SWITCH-CONTROLLED LIGHTING OUTLET
 SHALL BE INSTALLED IN HALLWAYS, STAIRWAYS, ATTACHED
 GARAGES, AND DETACHED GARAGES WITH ELECTRIC POWER. AT
 LEAST ONE WALL-SWITCH-CONTROLLED LIGHTING OUTLET SHALL
 BE INSTALLED TO PROVIDE ILLUMINATION ON THE EXTERIOR
 SIDE OF EACH OUTDOOR EGRESS DOOR HAVING GRADE LEVEL
 ACCESS, INCLUDING OUTDOOR EGRESS DOORS FOR ATTACHED
 GARAGES AND DETACHED GARAGES WITH ELECTRIC POWER. A
 VEHICLE DOOR IN A GARAGE SHALL NOT BE CONSIDERED AS AN
 OUTDOOR EGRESS DOOR. WHERE ONE OR MORE LIGHTING OUTLETS
 ARE INSTALLED FOR INTERIOR STAIRWAYS, THERE SHALL BE A
 WALL SWITCH AT EACH FLOOR LEVEL AND LANDING LEVEL THAT
 INCLUDES AN ENTRYWAY TO CONTROL THE LIGHTING OUTLETS
 WHERE THE STAIRWAY BETWEEN FLOOR LEVELS HAS SIX OR MORE
 RISERS.
 FRONT OF "A" AND "B"
  
 UNIT "A"
 SMOKE ALARM AT BOTTOM OF THE STAIRS
 OUTLET ON FRONT OUTSIDE
 OUTLET SPACING PER CODE
  
 UNIT "B"
 OUTLET AT FRONT OUTSIDE
 COUNTER OUTLET BY FRIDGE TO BE GFCI PROTECTED
 OUTLET SPACING PER CODE
  
  
  
  
  