| Date |
Text |
| 2017-04-19 19:20:30 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC FIFTH EDITION (2014) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) PROVIDE A DETAIL SHOWING HOW THE NEW PAVERS WILL |
| | TRANSITION INTO THE POOL COPING AROUND THE EXISTING |
| | POOL. FBC 107.2.1.3 |
| | |
| | 2) SPECIFY HOW THE NEW PAVERS WILL BE INSTALLED. WILL |
| | THEY BE SET IN MORTAR, EPOXIED, ETC. FBC 107.2.1.3 |
| | |
| | 3) SHOW COMPLIANCE WITH THE FOLLOWING ITEMS: |
| | |
| | - 454.1.2.5.3 STAIRS SHALL HAVE A MINIMUM TREAD WIDTH |
| | OF 10 INCHES (254 MM) AND A MAXIMUM WIDTH OF 48 INCHES |
| | (1219 MM) FOR A MINIMUM TREAD LENGTH OF 24 INCHES (610 |
| | MM) AND A MAXIMUM RISER HEIGHT OF 10 INCHES (254 MM). |
| | TREADS AND RISERS BETWEEN THE TOP AND BOTTOM TREADS |
| | SHALL BE UNIFORM TO WITHIN 1/2 INCH (12.7 MM) IN WIDTH |
| | AND HEIGHT. THE RISER HEIGHTS SHALL BE MEASURED AT THE |
| | MARKED STEP EDGES AND THE DIFFERENCES IN ELEVATION |
| | SHALL BE CONSIDERED THE RISER HEIGHTS. THE FRONT 3/4 TO |
| | 2 INCHES (19.1 TO 51 MM) OF THE TREAD AND THE TOP 2 |
| | INCHES (51 MM) OF THE RISER SHALL BE TILE, DARK IN |
| | COLOR, CONTRASTING WITH THE INTERIOR OF THE POOL. TILE |
| | SHALL BE SLIP RESISTANT. BULLNOSE TILE THAT IS SLIP |
| | RESISTANT MAY BE USED WHEN THE 3/4-INCH (19 MM) SEGMENT |
| | IS PLACED ON THE TREAD OR HORIZONTAL SURFACE AND THE |
| | 2-INCH (51 MM) SEGMENT IS PLACED ON THE RISER OR |
| | VERTICAL SURFACE. WHERE THE GUTTER IS USED AS THE TOP |
| | STEP, THE TILE ON THE GUTTER FOR THE WIDTH OF THE STEPS |
| | SHALL BE SLIP RESISTANT. VINYL LINER AND FIBERGLASS |
| | POOLS MAY USE OTHER MATERIAL FOR THE STEP EDGE MARKING, |
| | PROVIDED THE MATERIAL IS PERMANENT, PERMANENTLY |
| | SECURED, DARK IN COLOR, NONFADING AND SLIP RESISTANT. |
| | |
| | - 454.1.2.5.5 HANDRAILS SHALL BE PROVIDED FOR ALL |
| | STAIRS, SHALL BE ANCHORED IN THE BOTTOM STEP AND THE |
| | DECK. WHERE ?FIGURE 4" DECK-MOUNTED-TYPE HANDRAILS ARE |
| | USED, THEY SHALL BE ANCHORED IN THE DECK AND EXTEND |
| | LATERALLY TO ANY POINT VERTICALLY ABOVE THE BOTTOM |
| | STEP. GRABRAILS MUST BE MOUNTED IN THE POOL DECK AT |
| | EACH SIDE OF RECESSED STEPS. HANDRAILS AND GRABRAILS |
| | SHALL EXTEND BETWEEN 28 AND 40 INCHES (711 MM AND 1016 |
| | MM) ABOVE THE STEP EDGE AND DECK. |
| | |
| | - 454.1.3.1.1 POOL WET DECKS SHALL BE CONSTRUCTED OF |
| | CONCRETE OR OTHER NONABSORBENT MATERIAL HAVING A SMOOTH |
| | SLIP-RESISTANT FINISH. WET DECK AREA FINISHES SHALL BE |
| | DESIGNED FOR SUCH USE AND SHALL BE INSTALLED IN |
| | ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. |
| | |
| | - 454.1.3.1.2 POOL WET DECKS SHALL BE UNIFORMLY SLOPED |
| | AT A MINIMUM OF 2 PERCENT TO A MAXIMUM OF 4 PERCENT |
| | AWAY FROM THE POOL OR TO DECK DRAINS TO PREVENT |
| | STANDING WATER. TEXTURED DECK FINISHES THAT PROVIDE |
| | PITTING AND CREVICES OF MORE THAN 3/16 INCH (4.8 MM) |
| | DEEP THAT ACCUMULATE SOIL ARE PROHIBITED. IF SETTLING |
| | OR WEATHERING OCCURS THAT WOULD CAUSE STANDING WATER, |
| | THE ORIGINAL SLOPES SHALL BE RESTORED OR CORRECTIVE |
| | DRAINS INSTALLED. WHEN A CURB IS PROVIDED, THE DECK |
| | SHALL NOT BE MORE THAN 10 INCHES (254 MM) BELOW THE TOP |
| | OF THE CURB. |
| | |
| | - 454.1.3.1.3 POOL WET DECKS SHALL HAVE A MINIMUM |
| | UNOBSTRUCTED WIDTH OF 4 FEET (1219 MM) AROUND THE |
| | PERIMETER OF THE POOL, POOL CURB, LADDERS, HANDRAILS, |
| | DIVING BOARDS, DIVING TOWERS AND SLIDES. |
| | |
| | - 454.1.3.1.8 THE VERTICAL CLEARANCE ABOVE THE POOL |
| | DECK SHALL BE AT LEAST 7 FEET (2137 MM). |
| | |
| | |