2017-04-06 15:44:46RESIDENTIAL (R3) SUBMITTAL BUILDING REVIEW COMMENTS.
 CODE: FBC 5TH EDITION(2014).
  
 1- CUSTOM DOORS: CUSTOM DOORS NEED TO BE TESTED BY AN
 APPROVED TESTING LABORATORY OR ENGINEERED AS REQUIRED
 BY SEC. R612.2.1 FBC-RESIDENTIAL, 5TH EDITION (2014).
 ENGINEERED PACKAGE SUBMITTED NEEDS THE FOLLOWING FOR
 BUILDING OFFICIAL REVIEW AND APPROVAL:
 A) PROVIDE CURRENT APPROVED PRODUCT APPROVAL FOR
 SIMILAR DOORS THAT ARE LESS OR EQUIVALENT IN
 PERFORMANCE THAN THE PROPOSED DOORS FOR COMPARISON.
 ENGINEER TO PROVIDE COMPLETE COMPARATIVE ANALYSIS
 INFORMATION SHOWING THAT PROPOSED DOORS WILL MEET OR
 EXCEED THE PERFORMANCE OF THE APPROVED DOORS. NOTE: IN
 ORDER TO AVOID CONFLICTS OR DELAYS THE ENGINEER IS
 ADVISED TO SEE SEC. R612.3.1 FBC-RESIDENTIAL AND THE
 EXCEPTIONS TO USE AS A REFERENCE AS TO WHAT IS THE
 INFORMATION THAT NEEDS TO BE SUBMITTED FOR "COMPARATIVE
 ANALYSIS" FOR REVIEW.
  
 B) DRAWINGS SUBMITTED ARE INCOMPLETE AND INCORRECT.
 THERE ARE DRAWINGS SUBMITTED THAT DON'T APPLY TO THE
 PROPOSED CUSTOM DOORS. THERE IS NO GLAZING IN THE
 PROPOSED DOORS, THEREFORE THE ASTRO GUARD INFORMATION
 SUBMITTED IS NOT REQUIRED. ENGINEER TO PROVIDE ONLY THE
 DETAILS AND SPECIFICATIONS THAT MATCHES THE PROPOSED
 CUSTOM DOORS ASSEMBLY. SEC. 107.2.1 CITY AMENDMENTS.
  
 C) ENGINEER TO PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS FOR THE INSTALLATION OF THE DOORS FRAME
 TO THE OPENING ACTUAL CONDITIONS. THERE IS NOT WOODEN
 INFILL OPENING AS SPECIFIED ON THE SECOND PAGE OF THE
 LETTER SUBMITTED BY LAWRENCE L. GEORGE. SEE PLANS FOR
 CORRECT SUBSTRATE ON ALL SIDES AND PROVIDE COMPLETE
 DETAILS AND SPECIFICATIONS FOR ALL CONDITIONS. SEC.
 R301.1 FBC-RESIDENTIAL.
  
 D) ENGINEER TO PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS FOR THE CONSTRUCTION OF THE DOORS.
 SPECIFY PANELS SIZES, THICKNESS, REINFORCEMENT, WELDING
 SPECIFICATIONS, ETC. SEC. R301.1 FBC-RESIDENTIAL.
  
 E ) ENGINEER TO TO PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS FOR THE CONSTRUCTION OF DOORS FRAME.
 SPECIFY THE DOOR FRAME THICKNESS AND WELDING
 SPECIFICATIONS OR CORNER ATTACHMENT SPECIFICATIONS.
 SEC. R301.1 FBC-RESIDENTIAL.
  
 F) ENGINEER TO TO PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS FOR THE ATTACHMENT OF THE DOORS FRAME AT
 THE HEAD OF THE DOOR. SEC. R301.1 FBC-RESIDENTIAL.
  
 G) ENGINEER TO PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS FOR THE EXTERIOR TABS. SPECIFY THICKNESS
 AND WELDING SPECIFICATIONS TO THE DOOR FRAME. NOTE:
 ALSO, TAKE INTO CONSIDERATION ATTACHMENT TO THE
 STOREFRONT SYSTEM AS SHOWN ON PLANS. SEC. R301.1
 FBC-RESIDENTIAL.
  
 H) ENGINEER TO TO PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS FOR THE ATTACHMENT OF THE DOORS FRAME AT
 THE HEAD OF THE DOORS. SEC. R301.1 FBC-RESIDENTIAL.
  
 I) ENGINEER TO TO PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS FOR THE ATTACHMENT OF THE DOORS
 THRESHOLD. SEC. R301.1 FBC-RESIDENTIAL.
  
 J) ENGINEER TO TO PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS FOR THE DOORS HINGES. SEC. R301.1
 FBC-RESIDENTIAL.
  
 K) ENGINEER RESPONSIBLE FOR THE DESIGN NEEDS TO SIGN
 AND SEAL (ORIGINAL) EACH SHEET AS REQUIRED BY FAC
 61G15-23.002 AND CHAPTER 471 FLORIDA STATUTE.
  
 L) ENGINEER RESPONSIBLE FOR THE DESIGN NEEDS TO PROVIDE
 HIS TILE BLOCK WITH ALL THE REQUIRED INFORMATION ON
 EACH SHEET AS REQUIRED BY FAC 61G15-23.002 AND CHAPTER
 471 FLORIDA STATUTE.
  
 2- ENGINEER OF RECORD ON THIS HOUSE NEEDS TO REVIEW AND
 APPROVE IN WRITING (NOT SIGNING AND SEALING) THIS
 PRODUCT APPROVAL PRIOR TO SUBMITTAL TO THIS OFFICE.
 SEC. 107.3.4.1 CITY AMENDMENTS.
  