| 2017-05-05 14:30:58 | BUILDING PLAN REVIEW |
| | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 |
| | ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER, PX3169 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | |
| | 1ST REVIEW |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | 1. ROOFING PERMIT REQUIRED. |
| | 2. PROVIDE NOA'S/PRODUCT APPROVALS FOR NEW ROOF SYSTEM |
| | COMPONENTS. |
| | 3. PALM BEACH COUNTY IMPACT FEES REQUIRED. |
| | 4. NOA'S LISTED ON WINDOW AND DOOR SCHEDULE DO NOT |
| | MATCH PRODUCT APPROVALS SUBMITTED. CORRECT SCHEDULES ON |
| | SUBMITTED PLANS. |
| | 5. PROVIDE NOA'S FOR WINDOW MULLIONS. |
| | 6. PROVIDE DEMENSIONS FOR LANDING AT BOTTOM OF STAIRS. |
| | 7. GUARDS AT STAIRS AND BALCONY - A. HEIGHT - 42" B. |
| | MAX OPENING - 4". |
| | 8. TWO DIFFERENT PLAN PAGES ARE LABELED S-2. PLEASE |
| | CLARIFY. |
| | |
| | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | SPECIFICALLY, PROVIDE ROOFING, WINDOW, AND DOOR |
| | SUBMITTALS. |
| | |
| | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES |
| | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE |
| | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM |
| | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH |
| | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT |
| | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE |
| | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL |
| | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
| | |
| | R311.7 STAIRWAYS. |
| | |
| | R311.7.6 LANDINGS FOR STAIRWAYS. |
| | THERE SHALL BE A FLOOR OR LANDING AT THE TOP AND BOTTOM |
| | OF EACH STAIRWAY. THE MINIMUM WIDTH PERPENDICULAR TO |
| | THE DIRECTION OF TRAVEL SHALL BE NO LESS THAN THE WIDTH |
| | OF THE FLIGHT SERVED. LANDINGS OF SHAPES OTHER THAN |
| | SQUARE OR RECTANGULAR SHALL BE PERMITTED PROVIDED THE |
| | DEPTH AT THE WALK LINE AND THE TOTAL AREA IS NOT LESS |
| | THAN THAT OF A QUARTER CIRCLE WITH A RADIUS EQUAL TO |
| | THE REQUIRED LANDING WIDTH. WHERE THE STAIRWAY HAS A |
| | STRAIGHT RUN, THE MINIMUM DEPTH IN THE DIRECTION OF |
| | TRAVEL SHALL BE NOT LESS THAN 36 INCHES (914 MM). |
| | |
| | R311.7.8 HANDRAILS. |
| | HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF |
| | EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH FOUR OR |
| | MORE RISERS. R311.7.8.1 HEIGHT. |
| | HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED |
| | PLANE ADJOINING THE TREAD NOSING, OR FINISH SURFACE OF |
| | RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES (864 MM) |
| | AND NOT MORE THAN 38 INCHES (965 MM). |
| | |
| | SECTION 1013 GUARDS |
| | |
| | 1013.2 WHERE REQUIRED. |
| | GUARDS SHALL BE LOCATED ALONG OPEN-SIDED WALKING |
| | SURFACES, INCLUDING MEZZANINES, EQUIPMENT PLATFORMS, |
| | STAIRS, RAMPS AND LANDINGS THAT ARE LOCATED MORE THAN |
| | 30 INCHES (762 MM) MEASURED VERTICALLY TO THE FLOOR OR |
| | GRADE BELOW AT ANY POINT WITHIN 36 INCHES (914 MM) |
| | HORIZONTALLY TO THE EDGE OF THE OPEN SIDE. GUARDS SHALL |
| | BE ADEQUATE IN STRENGTH AND ATTACHMENT IN ACCORDANCE |
| | WITH SECTION 1607.8. |
| | |
| | 1013.3 HEIGHT. |
| | REQUIRED GUARDS SHALL NOT BE LESS THAN 42 INCHES (1067 |
| | MM) HIGH, MEASURED VERTICALLY AS FOLLOWS: |
| | |
| | 1. FROM THE ADJACENT WALKING SURFACES; |
| | |
| | 2. ON STAIRS, FROM THE LINE CONNECTING THE LEADING |
| | EDGES OF THE TREAD NOSINGS; AND |
| | |
| | 3. ON RAMPS, FROM THE RAMP SURFACE AT THE GUARD. |
| | |
| | 1013.4 OPENING LIMITATIONS. |
| | REQUIRED GUARDS SHALL NOT HAVE OPENINGS WHICH ALLOW |
| | PASSAGE OF A SPHERE 4 INCHES (102 MM) IN DIAMETER FROM |
| | THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT. |
| | |
| | |
| | |
| | |