2017-04-07 10:42:22FAILED
  
 1) DRAWING POR-WPB-103 - PROVIDE SITE PLAN WITH SETBACK
 FOR THE HIGH FREESTANDING SIGN ALONG OKEECHOBEE
 BOULEVARD AND DIRECTIONAL SIGN POR-WPB-603. PLEASE NOTE
 BOTH SIGNS REQUIRE A MINIMUM SETBACK OF FIVE (5) FEET.
  
 2) DRAWING POR-WPB-103 - DIRECTIONAL SIGN POR-WPB-603
 IS NOT SHOWN IN THE CORRECT LOCATION. THE SIGN IS
 APPROVED FURTHER SOUTH AND ALIGNED IN A NORTH/SOUTH
 DIRECTION.
  
 3) DRAWING POR-WPB-103 - THE CUSTOMER PARKING SIGNS
 POR-WPB-602 ARE SHOWN WITHIN THE REQUIRED TWO FOOT
 OVERHANG BETWEEN THE BACK OF THE WHEEL STOP AND THE END
 OF THE PARKING SPACE. THE SIGNS MAY NOT BE LOCATED
 WITHIN THIS AREA.
  
 4) DRAWING POR-BRAMAN-201B INCORRECTLY LABELS THE
 PORSCHE AND BRAMAN SERVICE SIGNS. THE DRAWING SHALL
 SHOW CORRECT CONDITIONS.
  
 5) WALL SIGNS - SOUTH PERMITTED = 1,100 SF
  
 PL ? 30 PORSCHE = 91.5 SF
 BRAMAN = 21.5 SF
 SERVICE = 24.9 SF
 TOTAL = 137.9 SF
  
 6) DRAWING POR-WPB-301 PORSCHE SIGN COMPLIES WITH
 MASTER SIGN PLAN
  
 7) DRAWING POR-WPB-302 BRAMAN SIGN COMPLIES WITH MASTER
 SIGN PLAN
  
 8) DRAWING POR-WPB-303 - PLEASE EXPLAIN WHAT IS BEING
 SHOWN AS THE 45 DEGREE ANGLE PORTION OF THE PORSCHE
 SERVICE SIGN ON THE SIDE VIEW. THE OTHER SIGN VIEWS DO
 NOT SHOW THIS PROJECTION. PLEASE NOTE THAT SIGNS MAY
 ONLY PROJECT A MAXIMUM OF 18 INCHES FROM THE WALL. THE
 PLAN VIEW ALREADY SHOWS THE BODY OF THE SIGN AS
 PROJECTING 12 INCHES FROM THE WALL. THE 45 DEGREE ANGLE
 PORTION LOOKS TO PROJECT TWO TIMES FARTHER OUT.
  
 9) HIGH FREESTANDING SIGN DRAWING POR-WPB-401 - SIGN
 COMPLIES WITH MASTER SIGN PLAN
  
 10) DIRECTIONAL SIGN "SERVICE" DRAWING POR-WPB-603
  
 A. THE OVERALL SIGN HEIGHT IS PERMITTED TO BE 48
 INCHES, YET THE DIMENSION SHOWN BELOW THE PANELS IS 3
 FEET 4 INCHES, WHICH IS 48 INCHES. PLEASE CORRECT THIS
 MEASUREMENT (32 INCHES PERMITTED).
  
 B. THIS SIGN IS APPROVED FOR INSTALLATION IN A
 LANDSCAPE AREA. PLEASE EXPLAIN WHY IT IS SHOWN BOLTED
 TO AN EXISTING CONCRETE SLAB.
  
 11) DIRECTIONAL SIGN "CUSTOMER PARKING AND SERVICE"
 DRAWING POR-WPB-604
  
 A. THIS SIGN IS APPROVED FOR INSTALLATION IN A
 LANDSCAPE AREA. PLEASE EXPLAIN WHY IT IS SHOWN BOLTED
 TO AN EXISTING CONCRETE SLAB.
  
 12) CUSTOMER PARKING SIGNS DRAWING POR-WPB-602 - SIGN
 COMPLIES WITH MASTER SIGN PLAN
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  
  
2017-03-29 13:32:46ROUTED TO ERIC SCHNEIDER