| 2017-04-14 09:52:13 | BUILDING PLAN REVIEW |
| | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 |
| | ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER, PX3169 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | |
| | 1ST REVIEW |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA |
| | (SFHA). THE SPECIFIC ZONE DESIGNATION FOR THIS SITE IS |
| | A5 WITH A BASE FLOOD ELEVATION (BFE) OF 7 FEET, NGVD |
| | 29. THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO. |
| | 4658-16, (EFF. DATE 9-12-2016), REQUIRES AN ADDITIONAL |
| | 2 FEET OF FREEBOARD REQUIRING THE DESIGN FLOOD |
| | ELEVATION (DFE) TO BE 9. 0 FEET NGVD 29. PLEASE INSERT |
| | THIS INFORMATION ON YOUR PLANS. |
| | |
| | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS |
| | REQUIRED AT TIME OF PERMIT APPLICATION. |
| | NOTE: ALL EQUIPMENT SERVICING THE BUILDINGS ON THIS |
| | SITE ARE REQUIRED TO BE AT OR ABOVE 9.0 FEET NGVD. |
| | |
| | AN UNDER CONSTRUCTION ELEVATION CERTIFICATE IS |
| | RECOMMENDED. |
| | |
| | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS |
| | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL |
| | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. |
| | |
| | 1612.1 GENERAL. |
| | WITHIN FLOOD HAZARD AREAS AS ESTABLISHED IN SECTION |
| | 1612.3, ALL NEW CONSTRUCTION OF BUILDINGS, STRUCTURES |
| | AND PORTIONS OF BUILDINGS AND STRUCTURES, INCLUDING |
| | SUBSTANTIAL IMPROVEMENT AND RESTORATION OF SUBSTANTIAL |
| | DAMAGE TO BUILDINGS AND STRUCTURES, SHALL BE DESIGNED |
| | AND CONSTRUCTED TO RESIST THE EFFECTS OF FLOOD HAZARDS |
| | AND FLOOD LOADS. FOR BUILDINGS THAT ARE LOCATED IN MORE |
| | THAN ONE FLOOD HAZARD AREA, THE PROVISIONS ASSOCIATED |
| | WITH THE MOST RESTRICTIVE FLOOD HAZARD AREA SHALL |
| | APPLY. |
| | |
| | 1612.4 DESIGN AND CONSTRUCTION. |
| | THE DESIGN AND CONSTRUCTION OF BUILDINGS AND STRUCTURES |
| | LOCATED IN FLOOD HAZARD AREAS, INCLUDING COASTAL HIGH |
| | HAZARD AREAS, SHALL BE IN ACCORDANCE WITH CHAPTER 5 OF |
| | ASCE 7 AND WITH ASCE 24. |
| | |
| | FBC 107.3.5.3 RESIDENTIAL (ONE AND TWO-FAMILY) & |
| | R322.2.1 ELEVATION REQUIREMENTS. BUILDINGS AND |
| | STRUCTURES IN FLOOD HAZARD AREAS NOT DESIGNATED AS |
| | COASTAL A ZONES SHALL HAVE THE LOWEST FLOORS ELEVATED |
| | TO OR ABOVE THE DESIGN FLOOD ELEVATION. PROVIDE FLOOD |
| | DESIGN INFORMATION ON THE PROPOSED SURVEY AND PROVIDE |
| | FLOOD ELEVATION CERTIFICATE. |
| | |
| | |
| | |