Plan Review Notes
Plan Review Notes For Permit 17011191
Permit Number 17011191
Review Stop P
Sequence Number 2
Notes
Date Text
2017-05-03 08:53:262ND REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS: PREVIOUS COMMENTS HAVE NOT BEEN
 COMPLIED WITH.
  
 1. THE LAVATORY STACKS SHOULD CONNECT TO THE WC BRANCH
 DRAIN NOT THE BUILDING DRAIN. PER WPB AMEND TO FBC
 107.2.1
  
 2. THE TUBS SHOULD CONNECT TO HORIZONTAL DRAIN FOR THE
 BATHROOM GROUP NOT THE VERTICAL STACK. PER WPB AMEND TO
 FBC 107.2.1
  
 DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND
 THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON
 RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  
  
 NEW COMMENT:
  
 1. THE PLUMBING AND ELECTRICAL SHEET SHALL BE SIGN AND
 SEALED BY THE DESIGNER OF RECORD. PER FAC 61G15-23.001