| 2017-02-01 11:38:28 | RESIDENTIAL (R3) REVISION, BUILDING REVIEW COMMENTS. |
| | CODE; FBC 5TH EDITION (2014). |
| | |
| | 1- PLANS SUBMITTED WERE REVISED. OWES $217.00 FOR |
| | REVISION FEES. |
| | NOTE: REVISION FEES APPLY EVERYTIME PLANS ARE REVISED |
| | TO ADDRESS COMMENTS. |
| | |
| | 2- ORIGINAL APPROVED PLANS WERE SIGNED AND SEALED BY |
| | THE PROFESSIONAL ENGINEER ERIC F. TRILLAS. THIS IS THE |
| | ENGINEER OF RECORD FOR THIS PROJECT. PLANS NEED THE |
| | SEAL, SIGNATURE AND TITLE BLOCK OF THE ENGINEER OF |
| | RECORD AS REQUIRED BY CHAPTER 471 FLORIDA STATUTE. |
| | |
| | 3- NONE OF THE REVISED WINDOWS ON BEDROOM #2 COMPLY |
| | WITH THE EGRESS REQUIREMENTS OF SEC. R310 |
| | FBC-RESIDENTIAL. APPROVED PLANS SPECIFIED BEDROOM |
| | WINDOW "P" AS 38" X 63" SINGLE HUNG WINDOW. PLANS WERE |
| | APPROVED BECAUSE THIS WINDOW WAS THE ONLY ONE THAT MET |
| | THE EGRESS REQUIREMENTS. REVISED PLANS DON'T SHOW ANY |
| | WINDOW THAT MEETS THE EGRESS REQUIREMENTS FOR BEDROOM |
| | #2. REVISE AS REQUIRED TO COMPLY WITH SEC. R310 |
| | FBC-RESIDENTIAL. |
| | NOTE: ORIGINALLY THIS ROOM WAS A "DEN ROOM" AND THE |
| | ENTRY DOOR WAS LOCATED IN THIS ROOM. ENTRY DOOR WAS |
| | RELOCATED, THEREFORE THE NEW BEDROOM NEEDS TO COMPLY |
| | WITH THE EGRESS REQUIREMENTS. |
| | |
| | 4- SHEET S3: ALL THE WINDOWS AND DOORS THAT ARE LOCATED |
| | WITHIN 4'-0" FROM THE CORNERS ARE CONSIDERED TO BE IN |
| | THE END ZONE. SOME WINDOWS ARE INCORRECTLY MARKED AS |
| | "A" FOR INTERIOR ZONE. REVISE INFORMATION ON EXTERIOR |
| | ELEVATIONS TO IDENTIFY ALL THE WINDOWS AND DOORS THAT |
| | ARE IN THE END ZONE. FIGURE R301.2(7) FBC-RESIDENTIAL. |
| | |
| | 5- BUILDING REVIEW WAS APPROVED ON 04/07/16 WITH THE |
| | FOLLOWING PROVISO: |
| | BUILDING REVIEW APPROVED WITH PROVISO: |
| | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR WINDOWS, |
| | WINDOW MULLIONS AND EXTERIOR DOOR. |
| | |
| | ONLY THE SINGLE HUNG PRODUCT APPROVAL WAS SUBMITTED UP |
| | TO THIS TIME. NEED PRODUCT APPROVAL (2 COPIES) FOR THE |
| | WINDOW MULLIONS AND EXTERIOR DOOR. |
| | |
| | 6- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS, |
| | INCLUDING SINGLE HUNG WINDOWS AS REQUIRED BY SEC. |
| | 107.3.4.1 CITY AMENDMENTS. |
| | |