| Date |
Text |
| 2017-05-02 19:00:48 | NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW |
| | CHECKLIST. |
| | CODE: FBC, 5TH EDITION (2014). |
| | |
| | NOTE: |
| | COMMENTS BELOW MAY BE APPROVED WITH PROVISO. PROVISO |
| | MEANS THAT CONTRACTOR AGREES TO PROVIDE THE REQUIRED |
| | INFORMATION AFTER THE PERMIT IS ISSUED BUT BEFORE |
| | INSPECTIONS TO AVOID CONFLICTS/DELAYS. NOTE: REVISION |
| | FEES MAY APPLY. CONTRACTOR TO ADVICE IN WRITING IF |
| | PROVISO OPTION IS PREFERRED AT THIS TIME. |
| | NEED THE COUNTY IMPACT FEES STAMP AND PAID RECEIPT IN |
| | ORDER TO PROCESS THE PERMIT. |
| | |
| | |
| | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) |
| | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED |
| | PLANS AND COPY OF PAID RECEIPT. COUNTY IMPACT FEE |
| | ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. |
| | |
| | 2- PROVIDE SURFACE DRAINAGE PLAN (2 COPIES) SHOWING |
| | COMPLIANCE WITH SEC. R401.3 FBC-RESIDENTIAL. |
| | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. |
| | |
| | 3- TRUSS PACKAGE: |
| | A) NEW COVER SHEET SUBMITTED NEEDS THE INFORMATION OF |
| | THE ENGINEER OF RECORD AS REQUIRED BY F.A.C. |
| | 61G15-31.003(5). |
| | |
| | B) TRUSS ENGINEER TO PROVIDE TITTLE BLOCK IN ALL SHEETS |
| | AS REQUIRED BY F.A.C. 61G15-31.003(5). |
| | |
| | NOTE: ONLY ONE COPY OF TRUSS PACKAGE WAS SUBMITTED. |
| | AFTER REQUIRED INFORMATION IS PROVIDED, CONTRACTOR MAY |
| | HANDLE ONE COPY OF THE TRUSS PACKAGE TO BUILDING |
| | INSPECTOR AT TIME OF FRAMING INSPECTIONS. PLEASE MAKE |
| | SURE PACKAGE IS REVIEWED BY THE ENGINEER OF RECORD. |
| | |
| | 4- REVISE ENERGY CALCULATIONS. |
| | A) WHY IT WAS ROTATED 225 DEGREES. PROVIDE CALCULATIONS |
| | FOR THE ACTUAL ORIENTATION OF THE PROPOSED BUILDING. |
| | B) REVISE # OF BEDROOMS TO MATCH PLANS. |
| | C) REVISE THE WINDOWS ORIENTATION, SQUARE FOOTAGE AND |
| | OVERHANG DEPTH TO MATCH PLANS. |
| | |
| | 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | FAC 61G20-3 FOR: |
| | A) SINGLE HUNG WINDOWS. WINDOW DRAWING NO 08-02546 |
| | SUBMITTED WITH FLORIDA PRODUCT APPROVAL FL17499 IS FOR |
| | NON-IMPACT WINDOWS. THESE WINDOWS DON'T MEET THE DESIGN |
| | PRESSURES SPECIFIED BY THE ENGINEER OF RECORD FOR |
| | WINDOWS LOCATED IN-THE END ZONE. IN ADDITION. WINDOW |
| | GLASS PROTECTION IS REQUIRED. |
| | |
| | B) HURRICANE MISSILE IMPACT PROTECTION FOR WINDOWS |
| | WITHOUT IMPACT GLASS. AND, PROVIDE COMPLETE SHUTTERS |
| | INSTALLATION SCHEDULE. SEE CITY SAMPLE. |
| | |
| | C) ENTRY DOORS: DRAWINGS SUBMITTED WITH FLORIDA PRODUCT |
| | APPROVAL FL15213-R2 ARE TOO SMALL AND ARE NOT LEGIBLE. |
| | PROVIDE LARGER AND CLEAR DRAWINGS. |
| | |
| | D) REAR FIBERGLASS DOOR. DRAWINGS SUBMITTED WITH |
| | FLORIDA PRODUCT APPROVAL FL15213-R2 ARE NOT FOR SINGLE |
| | DOORS AND ARE TOO SMALL AND ARE NOT LEGIBLE. PROVIDE |
| | CORRECT DRAWINGS AND LARGER AND CLEAR DRAWINGS. |
| | |
| | 6- ENGINEER OF RECORD TO APPROVE IN WRITING ABOVE |
| | PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY |
| | AMENDMENTS. |
| | |
| | ***PLEASE PROVIDE A RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| | ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD |
| | DRAWIINGS FOR REFERENCE. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |