| 2017-03-03 15:21:31 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC FIFTH EDITION (2014) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) FBC-R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. |
| | BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM |
| | SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND |
| | RESCUE OPENING. VERIFY THAT THE ADDITION WILL NOT |
| | INTERFERE WITH THE BEDROOM'S REQUIRED EMERGENCY EGRESS |
| | OPENING. |
| | |
| | 2) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS |
| | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC |
| | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE |
| | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER |
| | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH |
| | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS |
| | AND MAXIMUM DESIGN PRESSURES FOR THE ROOFING MATERIALS |
| | AND THE EXTERIOR DOOR. |
| | |
| | 3) ON SHEET S-1 THE ROOF PLAN SHOWS A ONE FOOT OVERHANG |
| | AND THE WALL SECTION HAS A TWO FOOT OVERHANG. PLEASE |
| | COORDINATE THE PLANS WITH THE CORRECT DIMENSIONS FOR |
| | THE OVERHANG. FBC 107.2.1 |
| | |
| | 4) THE SITE PLAN ON SHEET A-1 INDICATES THAT THE |
| | EXTERIOR WALL OF THE NEW ADDITION IS 3.58' FROM THE |
| | PROPERTY LINE. FBC-R302.1 REQUIRES THE UNDERSIDE OF THE |
| | ONE FOOT ROOF OVERHANG AT THE GABLE END TO BE ONE HOUR |
| | FIRE-RESISTANCE RATED IF IT IS LESS THAN THREE (3) FEET |
| | OF THE PROPERTY LINE. PROJECTIONS THAT ARE LESS THAN |
| | TWO (2) FEET OF THE PROPERTY LINE ARE NOT ALLOWED. |
| | |
| | 5) PROVIDE TWO SETS OF A DRAINAGE PLAN FOR THE ADDITION |
| | THAT SHOWS COMPLIANCE WITH FBC- R401.3 DRAINAGE. |
| | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER |
| | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT |
| | DOES NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN |
| | SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE |
| | SHALL FALL A MINIMUM OF 6 INCHES (152 MM) WITHIN THE |
| | FIRST 10 FEET (3048 MM). EXCEPTION: WHERE LOT LINES, |
| | WALLS, SLOPES OR OTHER PHYSICAL BARRIERS PROHIBIT 6 |
| | INCHES (152 MM) OF FALL WITHIN 10 FEET (3048 MM), |
| | DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE |
| | DRAINAGE AWAY FROM THE STRUCTURE. IMPERVIOUS SURFACES |
| | WITHIN 10 FEET (3048 MM) OF THE BUILDING FOUNDATION |
| | SHALL BE SLOPED A MINIMUM OF 2 PERCENT AWAY FROM THE |
| | BUILDING. |
| | |
| | 6) FBC ENERGY CONSERVATION SECTIONS R101.5.1.1.1 OR |
| | R101.5.1.1.2. SUBMIT TWO SETS OF ENERGY COMPLIANCE |
| | FORMS AS REQUIRED. |
| | |
| | 7) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A |
| | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW |
| | COMMENTS HAS BEEN ADDRESSED. |
| | |
| | |
| | |