| Plan Review Notes For Permit 17010600 |
| Permit Number |
17010600 |
|
| Review Stop |
R |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2017-02-23 14:32:35 | 1- FLAT ROOF NOA'S SUBMITTED (NOA 15-0203.05 AND | | | 14-1030.02): | | | A) CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY IS GOING TO | | | BE INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN | | | PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. NOTE: | | | COORDINATE WITH ITEM #5(C) ABOVE. IS IT GOING TO BE AN | | | INSULATED FLAT ROOF ASSEMBLY OR ROOF IS GOING TO BE | | | INSULATED BETWEEN ROOF JOISTS? | | | | | | B) PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS AS | | | REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF | | | NOA'S. CALCULATIONS ARE REQUIRED IF THE SELECTED | | | ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES FOR ALL ROOF | | | ZONES. | | | |
|