| 2017-01-28 07:46:04 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 17010585 |
| | ADD: 319 CLEMATIS ST. SUITE # 508 & 510 |
| | CONT: GERARD CONTRACTING |
| | TEL: 561-832-9785 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: SAT. JAN. 28/2017 |
| | ACTION: DENIED |
| | |
| | 1) SHEET A-1.0 THE ENTRY DOOR JUST TO THE RIGHT OF THE |
| | ELEVATOR LOBBY SHOWS AS NEW WORK AS IN FILL AN EXISTING |
| | OPENING. THE PLANS DO NOT PROVIDE COMPLIANCE FOR |
| | MANEUVERING CLEARANCES AT MANUAL SWING DOORS PER |
| | SCETION 404.2.4 OF THE 2014 FBC-ACCESSIBILITY CODE AND |
| | FIGURE 404.2.4.1 (A). MANEUVERING CLEARANCE OF 18 |
| | INCHES LATCH SIDE OF THE DOOR. |
| | |
| | 2) SHEET A-1.0 DETAIL D NEW BREAK ROOM ELEVATION SHOWS |
| | A SHELF HOLDING A MICROWAVE AT AN ELEVATION OF 4 FOOT |
| | 10 INCHES OR 58 INCHES ABOVE THE FINISH FLOOR. |
| | 2A) THE MICROWAVE MUST MEET ONE OF THE TWO REACH |
| | RANGES: |
| | 308.2.2 OBSTRUCTED HIGH REACH. |
| | 308.3.2 OBSTRUCTED HIGH REACH. |
| | |
| | 2B) 309.1. OPERABLE PARTS SHALL COMPLY WITH 309. |
| | 309.2 CLEAR FLOOR SPACE. A CLEAR FLOOR OR GROUND SPACE |
| | COMPLYING WITH 305 SHALL BE PROVIDED. |
| | 309.3 HEIGHT. OPERABLE PARTS SHALL BE PLACED WITHIN ONE |
| | OR MORE OF THE REACH RANGES SPECIFIED IN 308. |
| | 309.4 OPERATION. OPERABLE PARTS SHALL BE OPERABLE WITH |
| | ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, |
| | PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED |
| | TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS (22.2 N) |
| | MAXIMUM. |
| | |
| | 3) 202.4.1 DISPROPORTIONATE COST. THE CONTRACT VALUE AS |
| | STATED INDICATES A CONTRACT VALUE OF $31,500. THE 2014 |
| | FBC-ACCESSIBILITY CODE SECTION 202.4.1 CAN REQUIRE UP |
| | TO 20% ($6,300.00) OF THE CONTRACT VALUE IN ACCESSIBLE |
| | UPGRADES TO THE TENANT SPACE. THE SEQUENCE IN HOW THE |
| | FUNDS ARE TO BE SPENT WHICH ACCESSIBLE ELEMENTS TO |
| | PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE ELEMENTS |
| | THAT WILL PROVIDE THE GREATEST ACCESS, IN THE FOLLOWING |
| | ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN ACCESSIBLE |
| | ROUTE TO THE ALTERED AREA; (III) AT LEAST ONE |
| | ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX |
| | RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE |
| | DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL |
| | ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND |
| | ALARMS. |
| | |
| | PLEASE NOTE THE BATHROOM WITHIN THE TENANT SPACE DOES |
| | NOT MEET THE REQUIREMENTS FOUND IN THE 2014 |
| | FBC-ACCESSIBILITY CODE: |
| | 604.3.1 SIZE |
| | 604.4 SEATS. |
| | 604.5 GRAB BARS. |
| | 604.7 DISPENSERS |
| | 606.1 LAVATORIES AND SINKS SHALL COMPLY WITH 606. |
| | 608.1 SHOWER COMPARTMENTS SHALL COMPLY WITH 608. |
| | |
| | EITHER THE CONTRACTOROR DESIGNER OF RECORD SHALL ON |
| | THEIR LETTERHEAD PROVIDE A ITEMIZED LIST WHERE THE 20% |
| | IN FUNDS WILL BE SPENT ON THIS PROJECT AND ALSO REFLECT |
| | ON THE PLANS. |
| | |
| | 4) THE LIFE SAFETY SHEET IN ALL OF THE WHOLE FLOOR |
| | SHOWN AND IN THE WORK AREA INCLUSIVE OF THE ELEVATOR |
| | LOBBY THERE IS ONLY ONE EMERGENCY BATTERY BACK UP LIGHT |
| | INDICATED ON THE WHOLE FLOOR. 2014 FBC-B 1006.3.1 |
| | ILLUMINATION LEVEL UNDER EMERGENCY POWER. |
| | |
| | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER BN, PX, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | 401 CLEMATIS ST. |
| | WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |