Plan Review Notes
Plan Review Notes For Permit 17010476
Permit Number 17010476
Review Stop B
Sequence Number 1
Notes
Date Text
2017-01-23 11:31:31BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17010476 FENCE/ ALUMINUM RAILING
 PERMIT
 W. P. B. PERMIT: 16110448 POOL
 ADD: 7130 OKEECHOBEE BLVD.
 CONT: CLIMATROL QUALITY ALUM PRODUCTS
 TEL: 1-800-273-7857
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: MON. JAN. 23/ 2017
 ACTION: DENIED
  
 1) THE SITE PLAN SHEET 1OF 1 BY J. MORTON LANDSCAPE
 ARCHITECT IS NOT SIGNED NOR SEALED. PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS PREPARED BY
 THE DESIGN PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE DESIGN
 PROFESSIONAL AFFIXED TO THE DOCUMENT.
  
 2) THE SITE PLAN SHEET 1OF 1 BY J. MORTON LANDSCAPE
 ARCHITECT SEEMS TO BE SHRUNK IN SCALE. NEITHER THE
 PERMIT APPLICATION NOR THE SITE PLANS HIGHLIGHT WHICH
 AREAS ARE TO BE FENCED IN. PLANS ARE TOO SMALL TO READ.
 PLANS INDICATE THE PLANS ARE DRAWN TO 1INCH=50 FEET. IN
 SCALING THE DRAWINGS THE PLANS ARE SHRUNK OVER 50 %.
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION 107.2.1.4 QUALITY OF BUILDING PLANS.
 BUILDING PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH
 SCALE UPON SUBSTANTIAL PAPER. THE BUILDING OFFICIAL MAY
 ESTABLISH THROUGH DEPARTMENTAL POLICY, OTHER STANDARDS
 FOR PLANS AND SPECIFICATIONS, IN ORDER TO PROVIDE
 CONFORMITY TO ITS RECORD RETENTION PROGRAM.
  
 3) PLEASE SEE COMMENT FROM THE POOL PERMIT AND HOW WILL
 COMPLIANCE BE ACCOMPLISHED. SHEET 1 OF 7 SHOW SECTIONS
 OF FENCING BY OTHERS BETWEEN BUILDINGS. THIS PLAN
 DEPICTS THE OUTLINE OF THE APARTMENT BUILDINGS AND
 RECREATION/ LEASING CENTER WHICH SURROUND THE POOL AND
 POOL DECK. THE BUILDING ELEVATION PLANS OF THESE
 BUILDINGS DOES NOT INDICATE HOW SEPARATION FROM THE
 APARTMENT PATIO DECKS (FIRST FLOOR) AND THE POOL AND
 POOL DECK AREAS AND COMPLIANCE WITH 2014 FBC-B
 454.1.3.1.9. ACCESS THROUGH THE BARRIER OR FENCE FROM
 DWELLING UNITS, SUCH AS HOMES, APARTMENTS, MOTEL ROOMS
 AND HOTEL ROOMS, SHALL BE THROUGH SELF-CLOSING,
 SELF-LATCHING LOCKABLE GATES OF 48 INCH (1219 MM)
 MINIMAL HEIGHT FROM THE FLOOR OR GROUND WITH THE LATCH
 LOCATED A MINIMUM OF 54 INCHES (1372 MM) FROM THE
 BOTTOM OF THE GATE OR AT LEAST 3 INCHES (76 MM) BELOW
 THE TOP OF THE GATE ON THE POOL SIDE.
  
 3) COMMENTS FROM THE POOL PERMIT: SHEET 1 OF 7 THE SAME
 POOL SEPARATION ISSUE OCCURS WITHIN THE RECREATION/
 LEASING BUILDING AND POOL/ POOL DECK AREA PLEASE SHOW
 COMPLIANCE WITH:
 2014 FBC-B 454.1.3.1.9. ACCESS THROUGH THE BARRIER OR
 FENCE FROM DWELLING UNITS, SUCH AS HOMES, APARTMENTS,
 MOTEL ROOMS AND HOTEL ROOMS, SHALL BE THROUGH
 SELF-CLOSING, SELF-LATCHING LOCKABLE GATES OF 48 INCH
 (1219 MM) MINIMAL HEIGHT FROM THE FLOOR OR GROUND WITH
 THE LATCH LOCATED A MINIMUM OF 54 INCHES (1372 MM) FROM
 THE BOTTOM OF THE GATE OR AT LEAST 3 INCHES (76 MM)
 BELOW THE TOP OF THE GATE ON THE POOL SIDE. IF THE
 SELF-CLOSING, SELF-LATCHING GATE IS ALSO SELF-LOCKING
 AND IS OPERATED BY A KEY LOCK, ELECTRONIC OPENER OR
 INTEGRAL COMBINATION LOCK, THEN THE OPERABLE PARTS OF
 SUCH LOCKS OR OPENERS SHALL BE 34 INCHES MINIMUM (864
 MM) AND 48 INCHES MAXIMUM (1219 MM) ABOVE THE FINISHED
 FLOOR OR GROUND.
 DOORED ACCESS POINTS FROM PUBLIC ROOMS SUCH AS LOBBIES
 OR CLUB HOUSES NEED NOT BE THROUGH GATES IF THE DOOR(S)
 MEET THE SAME SELF-CLOSING, SELF-LATCHING REQUIREMENTS
 AS A GATE. GATES SHALL OPEN OUTWARD AWAY FROM THE POOL
 AREA.
  
 THIS FENCE PERMIT A PAGE FROM THE 2014 FBC-B HAS
 SECTION 454.1.3.1.9 HIGHLIGHTED. PLEASE REVIEW 2014
 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH AMENDMENTS
 TO THE FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION
 SECTION 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 SUCH INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL
 CODES SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR
 SHALL THE TERM "LEGAL" OR
 ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION. SHOW COMPLIANCE ON THE PLANS!!!!
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved