| Plan Review Notes For Permit 17010184 |
| Permit Number |
17010184 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2017-02-13 07:35:46 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | PROVISO: | | | | | | 1008.1.10 PANIC AND FIRE EXIT HARDWARE. | | | DOORS SERVING A GROUP H OCCUPANCY AND DOORS SERVING | | | ROOMS OR SPACES WITH AN OCCUPANT LOAD OF 50 OR MORE IN | | | A GROUP A OR E OCCUPANCY SHALL NOT BE PROVIDED WITH A | | | LATCH OR LOCK UNLESS IT IS PANIC HARDWARE OR FIRE EXIT | | | HARDWARE. | | | | | | EXCEPTION: A MAIN EXIT OF A GROUP A OCCUPANCY IN | | | COMPLIANCE WITH SECTION 1008.1.9.3, ITEM 2. | | | |
|