| Plan Review Notes For Permit 16120849 |
| Permit Number |
16120849 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2017-01-04 08:35:49 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. GLAZED OPENINGS IN BUILDINGS LOCATED IN WINDBORNE | | | DEBRIS REGIONS SHALL BE PROTECTED FROM WINDBORNE DEBRIS | | | PER FBC R301.2.1.2. | | | 2. C OMPLY WITH ZONING COMMENTS AND RE-SUBMIT. | | | | | | R301.2.1.2 PROTECTION OF OPENINGS. | | | GLAZED OPENINGS IN BUILDINGS LOCATED IN WINDBORNE | | | DEBRIS REGIONS SHALL BE PROTECTED FROM WINDBORNE | | | DEBRIS. GLAZED OPENING PROTECTION FOR WINDBORNE DEBRIS | | | SHALL MEET THE REQUIREMENTS OF THE LARGE MISSILE TEST | | | OF ASTM E 1996 AND ASTM E 1886 REFERENCED THEREIN, SSTD | | | 12, TAS 201, 202 AND 203 OR AAMA 506, AS APPLICABLE. | | | THE APPLICABLE WIND ZONES FOR ESTABLISHING MISILE TYPES | | | IN ASTM E 1996 ARE SHOWN IN SECTION R301.2.1.2.1. | | | GARAGE DOOR GLAZED OPENING PROTECTION FOR WINDBORNE | | | DEBRIS SHALL MEET THE REQUIREMENTS OF AN APPROVED | | | IMPACT-RESISTING STANDARD OR ANSI/DASMA 115. | | | |
|