| Date |
Text |
| 2016-12-30 07:08:04 | 1) SUBMIT AN EXPANDED GAS RISER THAT CLEARLY SHOWS THE |
| | PIPE SIZES, PSI, TYPE OF PIPE, ETC. WPB AMEND. TO FBC |
| | SEC. 107.2.1. |
| | 2) SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS |
| | METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE |
| | OUTLET IN THE BUILDING AND / OR SYSTEM PER THE 2014 |
| | FBC-FUEL GAS SEC.402.4.1 OR 2014 FBC-RES. SEC. G |
| | 2413.3.SHOW THIS FOR THE 2 PSI SYSTEM AND ALSO THE LOW |
| | PRESSURE SYSTEM. |
| | 3.) SUBMIT CALCULATIONS FOR COMBUSTION AIR FOR THE |
| | FIREPLACE PER THE 2014 FBC-FUEL GAS CODE SEC.304.1 OR |
| | 2014 FBC-RES. SEC. G 2407. |
| | 4) SUBMIT MANUFACTURER'S SPECIFICATION SHEETS / |
| | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY |
| | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND |
| | FBC-2014 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2014 |
| | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED |
| | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS |
| | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF |
| | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. |
| | 5) SUBMIT TWO COPIES OF A HOUSE PLAN SHOWING THE |
| | LOCATION OF THE TANKLESS WATER HEATER AND THE LOCATION |
| | OF ANY OPERABLE DOORS OR WINDOWS. THE LOCATION OF THE |
| | WATER HEATER SHALL COMPLY WITH THE MANUFACTURER'S |
| | INSTALLATION INSTRUCTIONS. |
| | 6) A LISTED SHUTOFF VALVE SHALL BE INSTALLED |
| | IMMEDIATELY AHEAD OF EACH MP REGULATOR. THE GAS RISER |
| | APPEARS TO SHOW THE SHUTOFF VALVES DOWNSTREAM OF THE |
| | REGULATORS. |
| | 7) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE |
| | REGULATORS. WPB AMEND. TO FBC SEC. 107.2.1, 2014 |
| | FBC-FUEL GAS SEC.410.1, 410.2. |
| | 8) SUBMIT TWO COPIES OF THE SIZING TABLES USED IN THE |
| | DESIGN OF THIS SYSTEM OR PLACE THE NUMBER OF THE SIZING |
| | TABLES ON THE PLAN AND THE CODE STANDARD THAT WAS USED |
| | FOR THE SIZING OF THE SYSTEM. WPB AMEND. TO FBC SEC. |
| | 107.2.1, FBC-FUEL GAS SEC.402.3. |
| | 9) SHOW THE PIPE SIZE OF THE PE PIPE TO THE FIRE PIT. |
| | 10) SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE |
| | AND TERMINATION OF THE GAS VENTS (IF APPLICABLE) PER |
| | 2014 FBC-FUEL GAS SECS. 502 THRU 505 OR 2014 FBC-RES. |
| | SEC.G2426. |
| | |
| | TIM LARGE |
| | CHIEF PLUMBING INSPECTOR |
| | PLUMBING PLAN REVIEW |
| | 561-805-6692 |