| 2016-12-30 15:32:43 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16120779 |
| | ADD: 5601 S. DIXIE HWY/ SUITE # 5613 (PCN: |
| | 74-43-44-04-04-07-0010) |
| | CONT: TAB CONSTRUCTION/ CRC 038041 |
| | TEL: 561-389-0518 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: FRI. DEC. 30/2016 |
| | ACTION: DENIED |
| | |
| | 1) PLEASE CORRECT THE SITE ADDRESS AND UNIT ADDRESS SEE |
| | ADDRESS LISTED ABOVE. 2014 FLORIDA BUILDING CODE W 2014 |
| | WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION 107.2.1 INFORMATION ON |
| | CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE |
| | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE |
| | AND EXTENT OF THE WORK PROPOSED. |
| | |
| | 2) THE PERMIT APPLICATION UNDER THE HEADING OF |
| | LICENSURE LIST A CRC LICENSE, CERTIFIED RESIDENTIAL |
| | CONTRACTOR, PLEASE NOTE THIS IS OUT OF THE SCOPE OF |
| | WORK ALLOWED FOR A CRC LICENSE, SEE FLORIDA STATUTE |
| | 489. 105 (3)(C) RESIDENTIAL CONTRACTOR MEANS A |
| | CONTRACTOR WHOSE SERVICES ARE LIMITED TO CONSTRUCTION, |
| | REMODELING, REPAIR, OR IMPROVEMENT OF ONE-FAMILY, |
| | TWO-FAMILY, OR THREE-FAMILY RESIDENCES NOT EXCEEDING |
| | TWO HABITABLE STORIES ABOVE NO MORE THAN ONE |
| | UNINHABITABLE STORY AND ACCESSORY USE STRUCTURES IN |
| | CONNECTION THEREWITH. PLEASE HAVE A QUALIFIED |
| | CONTRACTOR APPLY FOR THE BUILDING PERMIT. |
| | |
| | 3) THE CONTRACTOR/ QUALIFIER WHO IS GOING TO PULL THE |
| | PERMIT AND SUPERVISE/ OVERSEE THE WORK IS THE ONE WHO |
| | CAN DRAW UP THE PLANS. THEY WILL NEED TO PRINT THEIR |
| | NAME, SIGN THEIR NAME AND PRINT THEIR LICENSE NUMBER ON |
| | THE PLANS THEY HAVE DRAWN. A CONTRACTOR CAN ONLY DRAW |
| | UP THE PLANS FOR WHICH THEY ARE LICENSED. 107.3.4 |
| | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE. |
| | |
| | 4) THE PLANS INDICATE THIS IS NOT A CHANGE OF OCCUPANCY |
| | BUT A CHANGE OF USE WITHIN THE SAME OCCUPANCY |
| | CLASSIFICATION . GOOGLE INDICATES THE LAST KNOWN USE |
| | FOR THIS TENANT SPACE TO BE A PSYCHIC. THE NEW USE IS |
| | TO BE GUSTOS GRILL, BOTH ARE UNDER THE BUSINESS |
| | OCCUPANCY. PLEASE PROVIDE A LIFE SAFETY PLAN SHOWING |
| | WHERE ALL KITCHEN EQUIPMENT WILL BE LOCATED, GRILLS, |
| | HOODS, STOVES, WORK TABLES, SINKS AND STORAGE FOR THE |
| | KITCHEN AREA. PLEASE PROVIDE WHERE THE TABLES AND |
| | CHAIRS WILL BE LOCATED IN THE PLAN AND PICK-UP AREA FOR |
| | TAKE OUT DINNERS. PLEASE SHOW THE EGRESS FOR THE PUBLIC |
| | AS WELL AS IN THE KITCHEN AREA. 107..3.5.1.1 MINIMUM |
| | REQUIREMENTS FOR COMMERCIAL PLAN REVIEW. |
| | 4A) PLEASE PROVIDE HOW THE PUBLIC WILL GAIN ENTRY INTO |
| | THE RESTROOM WITHOUT GOING THROUGH THE KITCHEN WORK |
| | AREA. |
| | |
| | 5) THE VALUE STATED FOR THE PROJECT IS EXTREMELY LOW |
| | FOR THE NEW CONSTRUCTION OF WALLS, PLUMBING,ELECTRICAL, |
| | MECHANICAL, EQUIPMENT, REFRIGARATION TABLES AND CHAIRS. |
| | 108.3* BUILDING PERMIT VALUATION. IF, IN THE OPINION OF |
| | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF |
| | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, |
| | MECHANICAL, OR PLUMBING SYSTEMS APPEARS TO BE UNDER |
| | ESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE |
| | DENIED. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE TOTAL REPLACEMENT PURPOSES, |
| | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL |
| | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRICAL, |
| | PLUMBING, MECHANICAL, INTERIOR FINISHES, NORMAL SITE |
| | WORK (EXCAVATION AND BACKFILL FOR BUILDINGS), |
| | ARCHITECTURAL AND DESIGN FEES, MARKETING COST, OVERHEAD |
| | AND PROFIT; EXCLUDING ONLY LAND VALUE. VALUATION |
| | REFERENCES MAY INCLUDE THE LATEST PUBLISHED DATA OF |
| | NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS |
| | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| | CONGRESS. |
| | |
| | 6) THE PLANS WILL ALSO NEED TO SHOW COMPLIANCE WITH |
| | 2014 FBC-ACCESSIBLITY CODE SECTION: |
| | 6A) 226.1. WHERE DINING SURFACES ARE PROVIDED FOR THE |
| | CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE |
| | SEATING SPACES AND STANDING SPACES AT THE DINING |
| | SURFACES SHALL COMPLY WITH 902. |
| | |
| | 6B) 226.2 DISPERSION. DINING SURFACES AND WORK SURFACES |
| | REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED |
| | THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING |
| | SURFACES AND WORK SURFACES. |
| | |
| | 6C) 227.1. WHERE PROVIDED, CHECK-OUT AISLES, SALES |
| | COUNTERS, SERVICE COUNTERS, FOOD SERVICE LINES, QUEUES, |
| | AND WAITING LINES SHALL COMPLY WITH 227 AND 904. |
| | |
| | 6D) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR |
| | SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD |
| | APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE |
| | COMPLYING WITH 306 SHALL BE PROVIDED. |
| | |
| | 6E) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND WORK |
| | SURFACES SHALL BE 28 INCHES (710 MM) MINIMUM AND 34 |
| | INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR |
| | GROUND. |
| | |
| | 7A) MEANS OF EGRESS IS NOT ALLOWED THROUGH KITCHENS |
| | 1014.2 NOR CAN THE RESTROOMS OPEN INTO ROOMS USED FOR |
| | THE PREPARATION OF FOOD FOR SERVICE TO THE PUBLIC. |
| | 1210.4. |
| | |
| | 7B) THE PROPOSED RESTROOM VESTIBULE IS NOT LARGE |
| | ENOUGH, DOES NOT COMPLY WITH ACCESSIBILITY CODE 404.2.6 |
| | (A) DOORS IN SERIES. |
| | |
| | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |