| 2017-02-15 18:30:21 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC FIFTH EDITION (2014) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) THE PERMIT AND PLANS SPECIFY THAT THIS PROJECT IS AN |
| | EXISTING COTTAGE THAT WILL BE REMODELED AND HAVE AND |
| | ADDITION. ALTHOUGH, A PERMIT APPLICATION FOR THIS WORK |
| | WAS APPLIED FOR, A PERMIT WAS NEVER ISSUED TO CONVERT |
| | THIS DETACHED GARAGE INTO LIVING SPACE. THERE IS AN |
| | AFFIDAVIT ON FILE DATED APRIL 29, 2016 THAT STATES THE |
| | WORK ON THE GARAGE CONVERSION WAS NEVER DONE. ANY WORK |
| | THAT WAS DONE TO THE DETACHED GARAGE WAS DONE SO |
| | WITHOUT PERMITS OR INSPECTIONS. PLEASE BE ADVISED THE |
| | INSPECTOR MAY REQUIRE PREVIOUSLY COMPLETED WORK TO BE |
| | MADE ACCESSIBLE AND OPEN FOR INSPECTION OR REQUIRE |
| | ADDITIONAL DOCUMENTATION FOR ALL CONCEALED WORK |
| | PREVIOUSLY COMPLETED PURSUANT TO FBC 110 & FBC 117. |
| | FBC 110.1 GENERAL - CONSTRUCTION OR WORK FOR WHICH A |
| | PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY |
| | THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK |
| | SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION |
| | PURPOSES UNTIL APPROVED. |
| | |
| | FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR |
| | TEST REPORTS AS PROOF OF COMPLIANCE. REQUIRED TESTS ARE |
| | TO BE MADE AT THE EXPENSE OF THE OWNER, OR AGENT, BY AN |
| | APPROVED TESTING LABORATORY OR OTHER APPROVED AGENCY. |
| | |
| | 2) THIS IS ALSO A CHANGE OF OCCUPANCY WITH NO CHANGE OF |
| | OCCUPANCY CLASSIFICATION. FBC EXISTING BUILDING SECTION |
| | 1001.2 |
| | |
| | 3) THE FRENCH DOOR THAT IS MARKED AS EXISTING DOOR ON |
| | THE PLANS WAS INSTALLED WITHOUT PERMITS OR INSPECTIONS. |
| | SUBMIT PRODUCT APPROVALS FOR THIS DOOR FOR REVIEW AS |
| | REQUIRED BY DCA RULE 9N-3. |
| | |
| | 4) SUBMIT THE PRODUCT APPROVALS FOR THE WALL LOUVER |
| | ATTIC VENTS AND PROVIDE DOCUMENTATION OF THE NET FREE |
| | AREA OF THE VENTS. THE REQUIRED NET VENT AREA IS 3.06 |
| | SQFT. SHOW COMPLIANCE WITH R806.1 VENTILATION REQUIRED |
| | OR R806.5 UNVENTED ATTIC AND UNVENTED ENCLOSED RAFTER |
| | ASSEMBLIES. FBC R806.1 ENCLOSED ATTICS AND ENCLOSED |
| | RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED |
| | DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE |
| | CROSS VENTILATION FOR EACH SEPARATE SPACE BY |
| | VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF |
| | RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE A LEAST |
| | DIMENSION OF 1/16 INCH (1.6 MM) MINIMUM AND 1/4 INCH |
| | (6.4 MM) MAXIMUM. VENTILATION OPENINGS HAVING A LEAST |
| | DIMENSION LARGER THAN 1/4 INCH (6.4 MM) SHALL BE |
| | PROVIDED WITH CORROSION-RESISTANT WIRE CLOTH SCREENING, |
| | HARDWARE CLOTH, OR SIMILAR MATERIAL WITH OPENINGS |
| | HAVING A LEAST DIMENSION OF 1/16 INCH (1.6 MM) MINIMUM |
| | AND 1/4 INCH (6.4 MM) MAXIMUM. OPENINGS IN ROOF FRAMING |
| | MEMBERS SHALL CONFORM TO THE REQUIREMENTS OF SECTION |
| | R802.1.8. REQUIRED VENTILATION OPENINGS SHALL OPEN |
| | DIRECTLY TO THE OUTSIDE AIR. |
| | |
| | 5) THE ENERGY COMPLIANCE FORM R405-2014 THAT WAS |
| | SUBMITTED CONTAINS ERRORS AND OMISSIONS. THIS IS NOT A |
| | MODEL THAT WILL BE WITH DIFFERENT ORIENTATIONS. THIS IS |
| | A ONE OF A KIND STRUCTURE AND IT IS SITE SPECIFIC. |
| | THEREFORE, YOU CAN NOT USE THE WORST CASE ORIENTATION |
| | ON THE FORM. USE THE ACTUAL ORIENTATION OF THE BUILDING |
| | FOR ENERGY AND EQUIPMENT SIZING CALCULATIONS. THERE |
| | WILL BE NO ROTATE ANGLE. THERE IS NO KITCHEN ( NOT |
| | ALLOWED BY ZONING REGULATIONS ). FBC 107.2.1 |
| | |
| | 6) THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR THE |
| | FRENCH DOORS HAS A NEGATIVE DESIGN PRESSURE THAT IS NOT |
| | ADEQUATE. THE PLANS REQUIRE +37.8, - 50.6 PSF AND THE |
| | PRODUCT IS RATED FOR +45, -45 PSF. FBC-R 301.2.1 |
| | |
| | 7) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS |
| | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 |
| | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT |
| | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION |
| | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR THE |
| | ROOFING MATERIAL THAT WILL BE INSTALLED ON THE FLAT |
| | ROOF. |
| | |
| | 8) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A |
| | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW |
| | COMMENTS HAS BEEN ADDRESSED. |
| | |