2016-12-07 14:13:42ROOFING PRODUCT APPROVAL:
 FLORIDA APPROVAL: FL 4891.2/ CLASSIC
 36 INCH WIDE W/ (4) 1.25 INCH HIGH RIBS MIN. 24 GA. 50
 OR 80 KSI STEEL.
 52.5 PSF @ MAXIMUM SUPPORT SPAN OF 60.187 INCHES ON
 CENTER
  
 SIDE WALL PANELS: \
 FLORIDA APPROVAL: FL 2686.2 CLASSIC
 36 INCH WIDE W/ (4) 1.25 INCH HIGH RIBS MIN. 26 GA. 50
 OR 80 KSI STEEL.
 +/- 40 PSF @ SUPPORT SPACING OF 60 INCHES O. C. FOR 50
 KSI PANELS
 +/- 45 PSF @ SUPPORT SPACING OF 60 INCHES O. C. FOR 80
 KSI PANELS
  
 THE DESIGN PRESSURESS FOR REDUCED SUPPORT SPACING MAY
 BE COMPUTED USING
 RATIONAL ANALYSIS PREPARED BY A FLORIDA PROFESSIONAL
 ENGINEER OR BY BASED ON
 NUCOR'S LOAD SPAN TABLE.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  