2017-08-04 15:09:30****PROVISOS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. BUILDING PROVISO: KAYKAN SOFFIT PRODUCT APPROVAL,
 INDICATE WHICH PRODUCT AND INSTALLATION METHOD IS
 PROPOSED (DRAWING PAGE 1 OF 15). SUBMIT TO BUILDING
 DIVISION PRIOR TO INSTALLATION.
  
 2. WHEN AVAILABLE, PROVIDE A COPY OF THE CONTRACT FOR
 THIS JOB, FBC 109. THIS MAY BE SENT VIA EMAIL. THE
 PERMIT WILL NOT BE ISSUED UNTIL THIS IS ADDRESSED.
  
 6. PRIOR TO INSTALLATION, SUBMIT TO BUILDING DIVISION
 FOR REVIEW:
  
 PROVIDE TEST REPORTS FOR THE FLOORING UNDERLAYMENT
 ACOUSTIC INSULATION:
  
 A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
  
 B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492.
  
 C. FBC B 720.2 OR 603.1, PROVIDE TEST DATA IN
 ACCORDANCE WITH ASTM E 84 OR UL 723 (FLAME SPREAD).
  
  
 *****************************************
 16111261 BLDG 1 (NORTH)
 16111265 BLDG 2
 16111259 CLUBHOUSE
  
 16111261 BUILDING DATA FOR C.O./REPORTING
 USC-404 TYPE 434 - ALT RESIDENTIAL
 SQUARE FEET - 69509
  
 CONSTRUCTION TYPE: 14-2-B
 UNITS:
 FLOORS: 4
 BEDROOMS:
 ROOMS:
 SQ FT LIVABLE: 69509
 SQ FT FOOTPRINT: 18480
 SQ FT ROOF: 18480
  
 SETBACKS FRONT (USE THIS TO ENTER VERTICAL DATUM IF
 KNOWN):
 SETBACKS BACK (USE THIS TO ENTER FIRST FLOOR IF KNOWN):
 XX.XX
 SETBACKS LEFT (USE THIS TO ENTER SECOND FLOOR IF KNOWN:
 XX.XX
 OCC LOAD:
 PROP USE: APARTMENT
 SPRINKLER SYS? Y
 SPRK REQ'D? Y
 BATHRMS:
  
 BLDG CODE: FL 2014
 OCC CLASS: 5TH ED R-2
  