| 2017-04-25 16:45:06 | 2ND REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. P3.4 THE HUB DRAIN SHALL CONNECT TO THE WET | | | VENT DOWN STREAM OF BRANCH DRAIN OF WATER CLOSET. FBC | | | PL 912.1 | | | | | | 2. SHT. P3.2 THE HUB DRAIN SHALL CONNECT TO THE WET | | | VENT DOWN STREAM OF BRANCH DRAIN OF THE LAVATORY. FBC | | | PL 912.1 | | | | | | 3.SHT. P3.8 THE NOTE UNDER THE TAG FOR RISER S-8 REFERS | | | TO SHT. P3.7 S-8 RISER IS NOT SHOWN ON P3.7 PLEASE | | | PROVIDE. | | | | | | 4. SHT P3.8 WATER CLOSET IN HALF BATH IS NOT VENTED IT | | | SHALL BE VENTED BEFORE IT CONNECTS TO THE BUILDING | | | DRAIN. PER FBC PL901.2.1 | | | | | | 5. SHT. P3.7 + P3-9 APEAR TO BE THE SAME PLEAS CLARIFY. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | | COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|