Plan Review Notes
Plan Review Notes For Permit 16111229
Permit Number 16111229
Review Stop B
Sequence Number 1
Notes
Date Text
2016-12-06 17:13:44BUILDING PLAN REVIEW
 W. P. B. REVISION: 16111229
 W. P. B. PERMIT: 16071135
 ADD: 1897 PALM BEACH LAKES BLVD UNITS 118,119,120,
 121,122 & 123.
 CONT: HALLMARK & SONS INC.
 TEL: 561-644-3498
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. DEC. 06/ 2016
 ACTION: DENIED
  
 1) SHEET A2, THE REVISION # 3 INDICATES IN UNIT 121 A
 NEW BREAK ROOM SINK AND CABINET. PLEASE PROVIDE
 COMPLIANCE WITH 2014 FBC-ACCESSIBILITY CODE;
 1A) 606.2 CLEAR FLOOR SPACE.
 1B) 606.3 HEIGHT.
 1C) 606.4 FAUCETS.
 1D) 606.5 EXPOSED PIPES AND SURFACES.
  
 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  