| Date |
Text |
| 2016-12-19 15:14:32 | RESIDENTIAL (R3) ADDITION, BUILDING REVIEW COMMENTS. |
| | CODE: FBC 5TH EDITION (2014). |
| | |
| | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) |
| | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED |
| | PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY |
| | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT |
| | CODE. |
| | NOTE: THIS MAY BE DONE LATER AT TIME OF ISSUING THE |
| | PERMIT. |
| | |
| | 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. |
| | R101.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| | |
| | 3- PROVIDE COMPLETE GABLE END DETAIL AND SPECIFICATIONS |
| | SHOWING COMPLIANCE WITH SEC. R609.4 FBC-RESIDENTIAL. |
| | |
| | 4- PROVIDE COMPLETE DETAIL AND SPECIFICATIONS FOR NEW |
| | CRICKET. IT LOOKS LIKE IS A BIG CRICKET. ROOF PLAN TO |
| | SHOW THE CRICKET LOCATION. NEED COMPLETE DETAIL SHOWING |
| | FRAMING MEMBERS AND FASTENERS SHOWING COMPLIANCE WITH |
| | SEC. R301.1 FBC-RESIDENTIAL. |
| | |
| | 5- SPECIFY CARBON MONOXIDE ALARMS FOR ALL BEDROOMS AS |
| | REQUIRED BY SEC. R315 FBC-RESIDENTIAL. |
| | |
| | 6- DESIGNER OF RECORD TO SPECIFY ROOF TILE FASTENING AS |
| | REQUIRED BY SEC. 107.2.1.2 CITY AMENDMENTS. IF |
| | SPECIFYING SCREWS, THEN SPECIFY SIZE AND NUMBER OF |
| | SCREWS. IF SPECIFYING ADHESIVE, THEN PROVIDE PRODUCT |
| | APPROVAL FOR THE ADHESIVE. |
| | |
| | 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | FAC 61G20-3.002(33) FOR: |
| | A) SLIDING GLASS WINDOWS AS SHOWN ON PLANS. |
| | |
| | B) WINDOWS AS SHOWN ON PLANS |
| | |
| | C) PRECAST LINTELS AS SHOWN ON PLANS. |
| | |
| | D) SIMPSON STRUCTURAL CONNECTORS AS SPECIFIED ON PLANS. |
| | NOTE: FLORIDA PRODUCT APPROVAL "F25" SPECIFIED ON SHEET |
| | 03 IS NOT A VALID FLORIDA PRODUCT APPROVAL NUMBER. |
| | REVISE AS REQUIRED. ALSO, FLORIDA PRODUCT APPROVALS |
| | LISTED ON SHEET D-1 ARE NO CURRENT. UPDATE TO THE |
| | CURRENT 2014 CODE. |
| | |
| | E) ROOF TILE AS SPECIFIED ON PLANS. |
| | |
| | F) PEEL AND STICK ROOF TILE UNDERLAYMENT AS SPECIFIED |
| | ON PLANS. |
| | |
| | G) ROOF TILE ADHESIVE IF SPECIFIED BY THE DESIGNER OF |
| | RECORD. SEE ROOF TILE PRODUCT APPROVAL FOR LISTED |
| | ADHESIVES. |
| | |
| | 8- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | ( NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | |
| | 9- STRUCTURAL NOTES ON SHEET 03: |
| | A) SPECIFICATIONS ON ROOF NAILING PATTERN DON'T MATCH |
| | SPECIFICATIONS SHOWN AT THE BOTTOM OF THE TRUSS |
| | CONNECTOR SCHEDULE ON THE SAME SHEET. REVISE AS |
| | REQUIRED TO MATCH. NOTE: SEC. R803.2.3.1 |
| | FBC-RESIDENTIAL REQUIRES 8D RING SHANK NAILS. IF USING |
| | 10D NAILS, THEN PROVIDE COMPLETE ENGINEERING SHOWING |
| | THAT 10D NAILS ARE EQUAL OR BETTER THAN 8D RING SHANK |
| | NAILS. |
| | |
| | B) REVISE STRUCTURAL NOTE #3. THE HIGH RIB METAL LATH |
| | REQUIRES 1-3/4" MIN. EMBEDMENT INTO THE WOOD MEMBER. |
| | REVISE THE SIZE OF NAIL SPECIFIED. 1-1/2" NAILS DON'T |
| | PROVIDE THE REQUIRED EMBEDMENT. ASTM C1063. |
| | |
| | 10- TRUSS PACKAGE SUBMITTED: |
| | A) ENGINEER TO PROVIDE ORIGINAL SIGNATURE (NOT COPY) AS |
| | REQUIRED BY CHAPTER 471 FLORIDA STATUTE. |
| | |
| | B) COVER PAGE IS MISSING THE INFORMATION OF THE DESIGN |
| | PROFESSIONAL OF RECORD. FAC SEC. 61G15-31.003. |
| | |
| | C) NEED THE TITLE BLOCK OF THE TRUSS ENGINEER ON EACH |
| | DRAWING AS REQUIRED BY FAC SEC. 61G15-31.003. |
| | |
| | D) DESIGN PROFESSIONAL OF RECORD TO REVIEW AND APPROVE |
| | ALL TRUSS DRAWINGS AS REQUIRED BY FAC SEC. |
| | 61G15-31.003. |
| | NOTE: CHECK PROFILE OF TRUSSES AT BOTH ENDS. THEY DON'T |
| | MATCH PROFILES SHOWN ON PLANS. |
| | |
| | 11- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO |
| | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, |
| | CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN |
| | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY |
| | AMENDMENTS. VALUATION WAS REVISED TO $35,000. THE |
| | PERMIT FEE BALANCE IS $315.52. |
| | |
| | ***PLEASE PROVIDE RESPONSE LETTER ADDRESING EACH |
| | COMMENT TO EXPEDITE THE REVIEW PROCESS.. |
| | ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMITT OLD |
| | DRAWINGS FOR REFERENCE. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |