| 2016-11-27 04:50:32 | 1) SHT. CVR OF 10 - THE OCCUPANCY CLASSIFICATION IS |
| | LISTED AS "IIIB". THIS IS A MIXED OCCUPANCY. LIST ALL |
| | APPLICABLE OCCUPANCY TYPES AND THE CORRESPONDING |
| | OCCUPANT LOAD FOR EACH AREA IN ACCORDANCE WITH 2014 FBC |
| | CHAPTER 3 AND SEC.1004. |
| | 2) THIS IS A CHANGE OF OCCUPANCY AND SHALL COMPLY WITH |
| | THE PLUMBING FIXTURE REQUIREMENTS OF THE 2014 |
| | FBC-PLUMBING, LIST THE PREVIOUS OCCUPANCY ON THE PLANS. |
| | TABLE 403.1. |
| | 3) DRINKING FOUNTAINS ARE REQUIRED PER 2014 |
| | FBC-PLUMBING TABLE 403.1. A MINIMUM OF 2 DRINKING |
| | FOUNTAINS ARE REQUIRED PER TABLE 403.1 FOOTNOTE (E) AND |
| | 2014 FBC-ACCESS. SEC.211.2. SUBMIT ELEVATION DETAILS. |
| | 4) THE BREAK ROOM SINK SHALL COMPLY WITH THE 2014 |
| | FBC-ACCESS. SECS.212, 606 AND 305. SHOW THE HEIGHT OF |
| | THE TOP OF THE COUNTERTOP FROM THE FINISH FLOOR AND THE |
| | REQUIRED CLEAR FLOOR SPACE FOR THE SINK. |
| | 5) A SERVICE SINK IS REQUIRED PER 2014 FBC-PLUMBING |
| | TABLE 403.2. |
| | 6) SEPARATE FACILITIES ARE REQUIRED FOR MALES AND |
| | FEMALES PER TABLE 403.1 OF 2014 FBC-PLUMBING. |
| | 7) SHT. A-3 DETAIL 4 (A) - THE PLACEMENT OF THE GRAB |
| | BAR ON THE REAR WALL SHALL COMPLY WITH 2014 FBC- |
| | ACCESS. SEC. 604.5.2 & FIGURE 504.5.2. |
| | 8) THE GRAB BARS SHALL BE MEASURED TO THE TOP OF THE |
| | GRIPPING SURFACE PER THE2014 FBC-ACCESS. SEC. 609.4. |
| | 9) SHT.A-3 - DETAIL 5 - SHOWS THE TOP OF THE LAVATORY |
| | AT 40 INCHES ABOVE THE FINISH FLOOR AND 34 INCHES IS |
| | SHOWN TO THE BACKSPLAS. THE MAXIMUM HEIGHT OF THE |
| | LAVATORY SHALL COMPLY WITH 2014 FBC- ACCESS. SEC.606.3. |
| | 10) THE FLUSH HANDLE FOR THE WATER CLOSET SHALL BE |
| | LOCATED ON THE OPEN SIDE OF THE WATER CLOSET. |
| | FBC-ACCESS. SEC.604.6. |
| | 11) SHT.A-3 DETAIL 6 REFERENCES THE 2010 FBC. THIS |
| | SCOPE OF WORK SHALL COMPLY WITH 2014 FBC. |
| | 12) THE WALL FINISH IN THE NEW TOILET ROMM SHALL COMPLY |
| | WITH 2014 FBC SEC. 1210. |
| | 13) SUBMIT A SANITARY AND WATER RISER FOR REVIEW THAT |
| | SHOWS ALL PLUMBING FIXTURES (DRINKING FOUNTAIS, MOP |
| | SINK, BREAK ROOM SINK, WASHER, DOG WASH TUBS, WATER |
| | HEATER). |
| | 14) WILL THERE BE ANY HOSE BIBBS INSTALLED FOR WASHING |
| | DOWN THE DOG AREAS? IF SO, SHOW THEM ON THE WATER |
| | RISER. EACH HOSE BIBB SHALL BE EQUIPPED WITH SEPARATE |
| | SHUTOFF VALVE. FPC SEC.606.2. |
| | 15) HOT WATER IS REQUIRED TO THE NEW MOP SINK. 2014 FPC |
| | SEC.607.1. |
| | |
| | TIM LARGE |
| | CHIEF PLUMBING INSPECTOR |
| | PLUMBING PLAN REVIEW |
| | 561-805-6692 |
| | [email protected] |
| | |
| | |
| | |