| Date |
Text |
| 2017-11-16 10:54:27 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 2ND REVIEW: FBC FIFTH EDITION (2014) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS |
| | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC |
| | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE |
| | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER |
| | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH |
| | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS |
| | AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE ASPHALT |
| | ROOF SHINGLES AND THE WOOD FRONT DOOR SPECIFIED ON THE |
| | PLANS. |
| | |
| | 2) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE 6' |
| | WIDE SLIDING GLASS DOOR ARE NON-IMPACT RATED AND |
| | REQUIRES THE DOORS TO HAVE IMPACT PROTECTION DEVICES |
| | INSTALLED. SUBMIT TWO SETS OF PRODUCT APPROVALS AND AN |
| | INSTALLATION SCHEDULE FOR THE IMPACT PROTECTION |
| | DEVICES. FBC 107.3.4 |
| | |
| | 3) THE ENERGY FORMS R405-2014 THAT WERE SUBMITTED ARE |
| | MISSING INFORMATION AND CONTAIN ERRORS. PLEASE CORRECT. |
| | FBC ENERGY CONSERVATION SECTION R405.4 |
| | - THE FORMS ARE REQUIRED TO BE SIGNED BY THE |
| | OWNER/AGENT. |
| | - THE OWNER'S NAME SHOULD BE DANNY JONES. |
| | - BUILDER'S NAME IS MISSING. |
| | - JURISDICTION IS MISSING (604700). |
| | - THE ORIENTATION IS WRONG THE FRONT DOOR FACES EAST, |
| | NOT NORTH. |
| | - THE WINDOW AREA AND ORIENTATIONS DO NOT MATCH THE |
| | PLANS. |
| | - THE GLAZED AREA OF THE 6' WIDE SLIDING GLASS DOOR IS |
| | NOT SHOWN WITH THE WINDOWS. |
| | - IN ORDER TO USE THE 1:300 VENT RATIO THE PLANS MUST |
| | COMPLY WITH EXCEPTION NUMBER (2) OF FBC-R806.2. PROVIDE |
| | CALCULATIONS AND SHOW THE REQUIRED 40 PERCENT BUT NOT |
| | MORE THAN 50 PERCENT OF THE REQUIRED VENTILATING AREA |
| | PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF |
| | THE ATTIC ON THE PLANS. |
| | |
| | |
| | |
| | |