2016-12-06 11:02:11REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SPECIFY THE ROOF SLOPE ON THE PLANS. FBC R902
  
 2) SHEET D-1 IS TITLED A PROPOSED GARAGE. CORRECTION
 REQUIRED. FBC 107.2.1
  
 3) THE NOTE ON THE WALL SECTION ON SHEET D-1 SPECIFIES
 THE SOFFIT VENTS AT 6 INCHES (6") ON CENTER. PLEASE
 CLARIFY. FBC R806
  
 4) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3
 THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT
 APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION
 INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR EACH OF
 THE ROOFING MATERIALS, WINDOW/GLASS TYPES, AND EXTERIOR
 DOOR TYPES.
  
 5) FBC - R301.2.1.2 PROTECTION OF OPENINGS. GLAZED
 OPENINGS IN BUILDINGS LOCATED IN WINDBORNE DEBRIS
 REGIONS SHALL BE PROTECTED FROM WINDBORNE DEBRIS.
 GLAZED OPENING PROTECTION FOR WINDBORNE DEBRIS SHALL
 MEET THE REQUIREMENTS OF THE LARGE MISSILE TEST OF ASTM
 E 1996 AND ASTM E 1886 REFERENCED THEREIN, SSTD 12, TAS
 201, 202 AND 203 OR AAMA 506, AS APPLICABLE.
  
 6) GENERAL NOTE 10 ON D-1 INCORRECTLY SPECIFIES ACI 318
 - 05. THE 2011 EDITION OF ACI 318 IS REFERENCED IN THE
 2014 FBC.
  
 7) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A
 RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW
 COMMENTS HAS BEEN ADDRESSED.
  
  
  
  