| 2016-11-04 07:01:23 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. FS 471, 481, PROVIDE A STRUCTURAL DETAIL FOR THE | | | BIKE RACKS AND INSTALLATION. THEY ARE TO BE DESIGNED TO | | | RESIST WIND LOADS, FBC 1609. THE PRODUCT DATA PROVIDED | | | DOES NOT PROVIDE THE INFORMATION REQUIRED TO SHOW | | | RESISTANCE TO WIND LOADS AND LIVE LOADS AND IS NOT | | | PREPARED BY A DESIGN PROFESSIONAL. | | | | | | THE FOLLOWING INFORMATION IS LACKING: | | | | | | WIND DESIGN CRITERIA | | | IN GROUND MOUNT DETAIL DOES NOT SPECIFY AN IN GROUND | | | EMBEDMENT DIMENSION | | | MINIMUM DEPTH OF CONCRETE IS NOT SPECIFIED | | | CONCRETE STRENGTH NOT SPECIFIED | | | THE GRANULAR MATERIAL UNDER THE CONCRETE LACKS A | | | SPECIFICATION (AMOUNT REQUIRED, SIZE) | | | |
|