2016-12-14 11:27:41MECHANICAL PROVISO
  
 M1305.1.3 APPLIANCES IN ATTICS. ATTICS CONTAINING
 APPLIANCES SHALL BE PROVIDED WITH AN OPENING AND A
 CLEAR AND UNOBSTRUCTED PASSAGEWAY LARGE ENOUGH TO ALLOW
 REMOVAL OF THE LARGEST APPLIANCE, BUT NOT LESS THAN 30
 INCHES (762 MM) HIGH AND 22 INCHES (559 MM) WIDE AND
 NOT MORE THAN 20 FEET (6096 MM) LONG MEASURED ALONG THE
 CENTERLINE OF THE PASSAGEWAY FROM THE OPENING TO THE
 APPLIANCE. THE PASSAGEWAY SHALL HAVE CONTINUOUS SOLID
 FLOORING IN ACCORDANCE WITH CHAPTER 5 NOT LESS THAN 24
 INCHES (610 MM) WIDE. A LEVEL SERVICE SPACE AT LEAST 30
 INCHES (762 MM) DEEP AND 30 INCHES (762 MM) WIDE SHALL
 BE PRESENT ALONG ALL SIDES OF THE APPLIANCE WHERE
 ACCESS IS REQUIRED. THE CLEAR ACCESS OPENING DIMENSIONS
 SHALL BE A MINIMUM OF 20 INCHES BY 30 INCHES (508 MM BY
 762 MM), AND LARGE ENOUGH TO ALLOW REMOVAL OF THE
 LARGEST APPLIANCE.