| 2016-11-03 09:50:03 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC FIFTH EDITION (2014) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) THE BUILDING CODE AND THE STANDARDS THAT ARE |
| | SPECIFIED ON SHEET C-1 ARE INCORRECT. PLEASE UPDATE TO |
| | THE 2014 FBC, ASTM C94-09, ASTM C90-11B, ASTM C270-08A, |
| | ASTM A615-09 AND ASTM A307-07B. 2014 FBC CHAPTER 46. |
| | |
| | 2) THE DOOR FROM THE GARAGE TO THE RESIDENCE IS |
| | REQUIRED TO HAVE A SELF CLOSING DEVICE. FBC-R 302.5.1 |
| | |
| | 3) THE TOTAL AREA SHOWN IN THE CALCULATION TABLE ON |
| | SHEET A-1 SHOULD BE 5593 SQUARE FEET. PLEASE CORRECT. |
| | FBC 107.2.1 |
| | |
| | 4) ON SHEET A-3 THERE ARE TAGS FOR 1/A4 AND THERE IS NO |
| | CORRESPONDING DETAIL FOR THEM ON SHEET A-4. PLEASE |
| | CLARIFY. FBC 107.2.1 |
| | |
| | 5) THE PLANS DO NOT SPECIFY THE INSULATION IN THE WALLS |
| | THAT ARE ADJACENT TO THE UNCONDITIONED GARAGE. FBC |
| | ENERGY CONSERVATION SECTION R303 |
| | |
| | 6) ON SHEET A-4 THE TRUSS ANCHOR IDENTIFICATION TAGS |
| | DID NOT PRINT DARK ENOUGH AND ARE BARELY LEGIBLE. THEY |
| | ARE NOT ACCEPTABLE TO BE SCANNED FOR PUBLIC RECORDS. |
| | FBC 107.2.1.4 |
| | |
| | 7) PRODUCT APPROVALS WERE SUBMITTED FOR SKYLIGHTS. SHOW |
| | THE SIZE AND LOCATION OF THE SKYLIGHT(S) ON THE PLANS. |
| | FBC-R 301.2.1 |
| | |
| | 8) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS |
| | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 |
| | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT |
| | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION |
| | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR THE 16' |
| | WIDE SECTIONAL GARAGE DOOR. THE ONE THAT WAS SUBMITTED |
| | IS LIMITED TO 9' WIDE DOORS. |
| | |
| | 9) SUBMIT THE UPDATED 2014 CODE VERSION OF FL 10445 FOR |
| | THE FRONT DOORS. FBC 107.3.4 |
| | |
| | 10) SUBMIT TWO COPIES OF THE MANUFACTURER'S |
| | SPECIFICATIONS AND INSTALLATION INSTRUCTIONS FOR THE |
| | OUTDOOR BBQ AND ITS EXHAUST HOOD. FBC 107.2.1 |
| | |
| | 11) THE ENERGY COMPLIANCE FORM 405-10 THAT WAS |
| | SUBMITTED IS FOR THE 2010 FBC. SUBMIT TWO COPIES OF |
| | FORM 405-14 FOR THE 2014 FBC ENERGY CONSERVATION |
| | SECTION R405 |
| | |
| | 12) THE OWNER/AGENT IS REQUIRED TO SIGN AND DATE THE |
| | FORM 405-14. FBC ENERGY CONSERVATION SECTION R103.1.1.2 |
| | |
| | 13) THE ENERGY FORM LISTS A 50 GALLON GAS WATER HEATER |
| | AND THE PLANS SPECIFY TWO GAS TANKLESS WATER HEATERS. |
| | PLEASE CORRECT. FBC 107.2.1 |
| | |
| | 14) THE ENERGY CALCULATION FORMS STATE THAT THIS IS NOT |
| | A WORST CASE, THEN SPECIFIES A 90 DEGREE ROTATE ANGLE. |
| | THE ACTUAL ORIENTATION OF THE STRUCTURE ON THE LOT IS |
| | REQUIRED TO BE USED WHEN NOT USING WORST CASE. PLEASE |
| | CORRECT. FBC ENERGY CONSERVATION SECTION R405.4.2 |
| | |
| | 15) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT |
| | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW |
| | COMMENTS HAS BEEN ADDRESSED. |
| | |