| 2016-11-03 10:38:32 | BUILDING PLAN REVIEW |
| | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | BUILDING PLANS EXAMINER ? PX3169 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 2ND REVIEW |
| | RESULTS: DENIED |
| | |
| | CATEGORY IV SUNROOM. ELECTRICAL, MECHANICAL, ENERGY AND |
| | IMPACT NOT REQUIRED. |
| | |
| | 1. INCLUDE SGD AT MASTER BEDROOM ON APPLICATION OR |
| | REMOVE IT FROM PLANS. |
| | 2. ENCLOSING THE SCREEN ROOM WITH GLASS VOIDS THE |
| | EGRESS REQUIREMENTS FOR BEDROOM #2. DEMONSTRATE HOW YOU |
| | WILL PROVIDE EGRESS FROM THIS ROOM. |
| | 3. PROVIDE DEMENSIONS FOR ROUGH OPENINGS OF MASONRY |
| | WALLS. PROVIDE FRAMING DETAIL FOR EACH OPENING. |
| | 4. DESIGNER TO PRINT NAME AND SIGN PLANS. |
| | 5. SHOW LOCATION OF GFI AND SMOKE DETECTOR LISTED ON |
| | PLANS OR REMOVE FROM PLANS. |
| | |
| | |
| | R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. |
| | BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM |
| | SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND |
| | RESCUE OPENING. WHERE BASEMENTS CONTAIN ONE OR MORE |
| | SLEEPING ROOMS, EMERGENCY EGRESS AND RESCUE OPENINGS |
| | SHALL BE REQUIRED IN EACH SLEEPING ROOM. WHERE |
| | EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY |
| | SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES |
| | (1118 MM) MEASURED FROMTHE FINISHED FLOOR TO THE BOTTOM |
| | OF THE CLEAR OPENING. WHERE A DOOR OPENING HAVING A |
| | THRESHOLD BELOW THE ADJACENT GROUND ELEVATION SERVES AS |
| | AN EMERGENCY ESCAPE AND RESCUE OPENING AND IS PROVIDED |
| | WITH A BULKHEAD ENCLOSURE, THE BULKHEAD ENCLOSURE SHALL |
| | COMPLY WITH SECTION R310.3. THE NET CLEAR OPENING |
| | DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED |
| | BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND |
| | RESCUE OPENING FROM THE INSIDE. EMERGENCY ESCAPE AND |
| | RESCUE OPENINGS WITH A FINISHED SILL HEIGHT BELOW THE |
| | ADJACENT GROUND ELEVATION SHALL BE PROVIDED WITH A |
| | WINDOW WELL IN ACCORDANCE WITH SECTION R310.2. |
| | EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL OPEN |
| | DIRECTLY INTO A PUBLIC WAY, OR TO A YARD OR COURT THAT |
| | OPENS TO A PUBLIC WAY. |
| | |
| | EXCEPTIONS: |
| | 1. BASEMENTS USED ONLY TO HOUSE MECHANICAL EQUIPMENT |
| | AND NOT EXCEEDING TOTAL FLOOR AREA OF 200 SQUARE FEET |
| | (18.58 M2). |
| | 2. THE EMERGENCY ESCAPE AND RESCUE OPENING SHALL BE |
| | PERMITTED TO OPEN INTO A SCREEN ENCLOSURE, OPEN TO THE |
| | ATMOSPHERE, WHERE A SCREEN DOOR IS PROVIDED LEADING |
| | AWAY FROM THE RESIDENCE. |
| | |
| | R612.8.4 MASONRY ROUGH OPENINGS. |
| | MASONRY ROUGH OPENING DIMENSIONS SHALL BE WITHIN THE |
| | TOLERANCES SPECIFIED AT SECTION R606.16 AND, IN |
| | ADDITION, SHALL PROVIDE FOR A WINDOW PERIMETER SEALANT |
| | JOINT A MAXIMUM OF 1/4 INCHES (6.4 MM) IN WIDTH. |
| | |
| | FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL |
| | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING |
| | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON |
| | RESPONSIBLE FOR THE DESIGN. |
| | |
| | |
| | |