| 2016-10-17 10:29:01 | BUILDING PLAN REVIEW |
| | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | BUILDING PLANS EXAMINER ? PX3169 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 1ST REVIEW |
| | RESULTS: DENIED |
| | |
| | 1. SPECIFY NEW DECKING MATERIAQL. |
| | 2. PROVIDE DETAIL FOR RE-INFORCING FOR ALL NEW |
| | STRUCTURAL CONCRETE. |
| | 3. PROVIDE SITE PLAN, IDENTIFY POOL BARRIER PER FBC |
| | 454.1.3.1.9. |
| | |
| | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | CONSTRUCTION DOCUMENTS SHALL BE |
| | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. |
| | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK |
| | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE |
| | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, |
| | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING |
| | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL |
| | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, |
| | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS |
| | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH |
| | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES |
| | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE |
| | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE |
| | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, |
| | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE |
| | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE |
| | DESIGN. (SEE ALSO SECTION 107.3.5). |
| | |
| | SECTION 454 SWIMMING POOLS AND BATHING PLACES (PUBLIC) |
| | 454.1.3.1.9 |
| | |
| | ALL PUBLIC POOLS SHALL BE SURROUNDED BY A MINIMUM 48 |
| | INCH (1219 MM) HIGH FENCE OR OTHER APPROVED SUBSTANTIAL |
| | BARRIER. THE FENCE SHALL BE CONTINUOUS AROUND THE |
| | PERIMETER OF THE POOL AREA THAT IS NOT OTHERWISE |
| | BLOCKED OR OBSTRUCTED BY ADJACENT BUILDINGS OR |
| | STRUCTURES AND SHALL ADJOIN WITH ITSELF OR ABUT TO THE |
| | ADJACENT MEMBERS. ACCESS THROUGH THE BARRIER OR FENCE |
| | FROM DWELLING UNITS, SUCH AS HOMES, APARTMENTS, MOTEL |
| | ROOMS AND HOTEL ROOMS, SHALL BE THROUGH SELF-CLOSING, |
| | SELF-LATCHING LOCKABLE GATES OF 48 INCH (1219 MM) |
| | MINIMAL HEIGHT FROM THE FLOOR OR GROUND WITH THE LATCH |
| | LOCATED A MINIMUM OF 54 INCHES (1372 MM) FROM THE |
| | BOTTOM OF THE GATE OR AT LEAST 3 INCHES (76 MM) BELOW |
| | THE TOP OF THE GATE ON THE POOL SIDE. IF THE |
| | SELF-CLOSING, SELF-LATCHING GATE IS ALSO SELF-LOCKING |
| | AND IS OPERATED BY A KEY LOCK, ELECTRONIC OPENER OR |
| | INTEGRAL COMBINATION LOCK, THEN THE OPERABLE PARTS OF |
| | SUCH LOCKS OR OPENERS SHALL BE 34 INCHES MINIMUM (864 |
| | MM) AND 48 INCHES MAXIMUM (1219 MM) ABOVE THE FINISHED |
| | FLOOR OR GROUND. DOORED ACCESS POINTS FROM PUBLIC ROOMS |
| | SUCH AS LOBBIES OR CLUB HOUSES NEED NOT BE THROUGH |
| | GATES IF THE DOOR(S) MEET THE SAME SELF-CLOSING, |
| | SELF-LATCHING REQUIREMENTS AS A GATE. GATES SHALL OPEN |
| | OUTWARD AWAY FROM THE POOL AREA. A LATCHED, LOCKABLE |
| | GATE SHALL BE PLACED IN THE FENCE WITHIN TEN FEET (3048 |
| | MM) OF THE CLOSEST POINT BETWEEN THE POOL AND THE |
| | EQUIPMENT AREA FOR SERVICE ACCESS. |
| | |
| | |