| Plan Review Notes For Permit 16090832 |
| Permit Number |
16090832 |
|
| Review Stop |
R |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2016-10-18 12:59:47 | PRODUCT APPROVAL FL2948-R9 WAS SUBMITTED. USE OF A | | | DIFFERENT PRODUCT APPROVAL REQUIRES APPROVAL BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL AS A REVISION. | | | PRIOR TO INSTALLATION, A SEPARATE ROOF PERMIT IS | | | REQUIRED. THE APPLICANT IS TO SUBMIT THE APPROVED | | | ASSEMBLY PROPOSED WITH ANY REQUIRED ENGINEERING. | | | | | | ROOF COVERING TO COMPLY WITH THE DESIGN PRESSURES SHOWN | | | ON S003: | | | | | | VULT | | | ZONE 1, -129/+52 | | | ZONE 2, -216/+52 | | | ZONE 3, -161 | | | | | | PLAN VIEW "ZONE 2" (NOT ZONE 2 PER ASCE7-10) IS ENTIRE | | | PERIMITER (ASCE7 ZONE 2 & 3). PLAN VIEW "ZONE 3" | | | APPEARS TO BE 1ST STORY ASCE 7 ZONES 2 & 3. | | | SEE PLAN ON SHEET S003 FOR FURTHER CLARIFICATION. | | | | | | | | | | | | | | | | | | |
|