| Date |
Text |
| 2016-10-14 05:21:45 | 1) SHT. A1.0 - PLUMBING FIXTURE TABLE NOTES 0 URINALS |
| | PROVIDED BUT ONE IS SHOWN IN THE MEN'S RESTROOM. |
| | CLARIFY. |
| | 2) SHT. A4.3 - THE GRAB BARS SHALL BE MEASURED TO THE |
| | TOP OF THE GRIPPING SURFACE PER FAC SEC. 609.4. |
| | 3) SHT. A4.3 - THESE DETAILS ARE FROM AN OUTDATED |
| | ACCESSIBILITY CODE. PLEASE REMOVE THIS SHEET FROM THE |
| | SET. |
| | 4) CLARIFY WHAT OPERATIONS/ PROCESSES WILL BE DONE AT |
| | THE "LIVE KITCHEN". |
| | 5) SHT. A1.0 - CLARIFY THE OCCUPANCY "M " MERCANTILE |
| | WAREHOUSSE. A WAREHOUSE IS CONSIDERED A STORAGE |
| | OCCUPANCY (S1 OR S2). CLARIFY. |
| | 6) SHT. A4.2 SHOWS NEW TOILET COMPARTMENT PARTITIONS. |
| | TOILET COMPARTMENT DOORS SHALL NOT SWING INTO THE |
| | MINIMUM REQUIRED CCOMPARTMENT AREA. 2014 FAC |
| | SEC.604.8.2.2. |
| | 7) THE TOILET PAPER DISPENSERS IN THE HANDICAPPED |
| | ACCESSIBLE COMPARTMENTS SHALL BE LOCATED 7-9 INCHES |
| | MAXIMUM IN FRONT OF THE WATEER CLOSET MEASURED TO THE |
| | CENTERLINE OF THE DISPENSER. FAC 604.7. |
| | 8) THE RELOCATED DRINKING FOUNTAINS SHALL CCOMPLY WITH |
| | FAC SEC. 307 FOR PROTRUSION LIMITS. |
| | 9) SHT. A4.2 - DETAIL #1- THE WATER CLOSET IN THE MEN'S |
| | ACCESSIBLEE TOILET COMPARTMENT SHALL BE LOCATED IN THE |
| | CORNER DIAGONAL TO THE DOOR.FAC 604.8.1.7. THE OTHER |
| | SHEETS SHOW THE WATER CLOSET IN THE CORRECT LOCATION. |
| | CLARIFY. |
| | 10) SHOW THE LOCATION OF THE REQUIRED SERVICE SINK AND |
| | INDICATE IF IT IS NEW OR EXISTING. IF IT IS NEW, HOT |
| | WATER SHALL BE SUPPLIED PER 2014 FPC SEC.607.1. |
| | |
| | TIM LARGE |
| | CHIEF PLUMBING INSPECTOR |
| | PLUMBING PLAN REVIEW |
| | 561-805-6692 |
| | [email protected] |
| | |