| Plan Review Notes For Permit 16090373 |
| Permit Number |
16090373 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2016-10-13 13:05:17 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. ENGINEERING REFERS TO A MIAMI DADE NOA, PRODUCT | | | APPROVAL SUBMITTED IS A FLORIDA STATE PRODUCT APPROVAL. | | | ENGINEERING IS TO BE CONSISTENT WITH THE PRODUCT | | | APPROVAL. | | | | | | 2. FBC 5TH EDITION RESIDENTIAL 301, THE ENGINEERING | | | DOES NOT REFER TO THE APPROVED ASSEMBLY SELECTED. | | | REVISE ENGINEERING TO INCLUDE EITHER THE ASSEMBLY | | | NUMBER OR PAGE NUMBER. | | | | | | 3. ENGINEERING IS TO INCLUDE A COMPLETE TITLE BLOCK IN | | | COMPLIANCE WITH FS471 AND FAC61G15-23.002. THE | | | ENGINEER'S PRINTED NAME, LICENSE NUMBER, CERTIFICATE OF | | | AUTHORIZATION ARE LACKING. THE SEAL IS REQUIRED TO | | | INCLUDE A DATE. | | | | | | 4. CONTRACTOR'S ROOF DRAWING STATES THAT ZONE 2 AND 3 | | | WILL BE 3'. FOUR FEET IS REQUIRED AS A MINIMUM, SEE FBC | | | 5TH EDITION RESIDENTIAL R301.2(7) FOOTNOTE REGARDING | | | DIMENSION A. REVISE ROOF PLAN. | | | |
|