Plan Review Notes
Plan Review Notes For Permit 16090343
Permit Number 16090343
Review Stop P
Sequence Number 1
Notes
Date Text
2016-10-03 08:28:111ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. PLEASE SHOW ACCESSIBILITY COMPLIANCE FOR THE BAR
 SINK. PER FBC ACC 606.2 CLEAR FLOOR SPACE.
 A CLEAR FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR
 A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
 606.3 HEIGHT.
 LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT
 OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES
 (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 2. PLEASE SHOW ACCESSIBILITY COMPLIANCE FOR THE
 LAVATORY'S. PER FBC ACC 606.2 CLEAR FLOOR SPACE.
 A CLEAR FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR
 A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
 606.3 HEIGHT.
 LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT
 OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES
 (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 3. SHOW CENTER OF WATER CLOSET OFF SIDE WALL 16" MIN.
 18" MAX. PER FBC ACC 604.2
  
 4. PLEASE PROVIDE WATER RISER DIAGRAM. PER WPB AMEND.TO
 FBC 107.3.5.1.3(13)
  
 5. PLEASE PROVIDE OCCUPANT LOAD, IF OVER 15 A WATER
 FOUNTAIN IS REQUIRED PER FBC ACC TABLE 403.1