| Date |
Text |
| 2016-10-11 10:31:49 | 1ST REVIEW |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER LL |
| | CITY OF WEST PALM BEACH |
| | DEVELOPMENT SERVICES |
| | BUILDING DIVISION |
| | 561-805-6711 |
| | [email protected] |
| | |
| | GAS COMMENTS: |
| | |
| | 1. THE PLUMBING AND GAS DRAWINGS SHALL BE SIGNED BY THE |
| | PERSON RESPONSIBLE FOR THE DESIGN. IF BY CONTRACTOR THE |
| | LIC. NUMBER IS REQUIRED. PER WPB AMEND. TO BC 107.2.1 |
| | |
| | 2. PLEASE PROVIDE A PLAN SHOWING THE LOCATION OF GAS |
| | METER AND ALL APPLIANCES. PER WPB AMEND. TO BC 107.2.1 |
| | |
| | 3.ENERGY PERFORMANCE INDICATES A PROPANE GAS HEATER THE |
| | RISER INDICATES NATURAL GAS PLEASE CLARIFY. PER WPB |
| | AMEND. TO BC 107.2.1 |
| | |
| | 4. THE ELECTRIC SHEET SHOWS WATER HEATER INSIDE GARAGE, |
| | PE PIPE IS NOT ALLOWED TO BE RUN UNDER THE BUILDING. |
| | PER FBC RES |
| | G2415.17.1 (404.17.1) |
| | |
| | 5. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL |
| | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER |
| | FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. |
| | |
| | 6. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, |
| | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING |
| | AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ? |
| | USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE |
| | SEC. 402.4.1. |
| | |
| | 7. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE |
| | FBC-2014 FUEL GAS CODE SEC. 304. |
| | |
| | 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND |
| | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE |
| | SEC. 502 THRU 505. |
| | |
| | 9. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL |
| | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA |
| | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 |
| | |
| | 10.BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON |
| | THE SYSTEM. BBQ NOT SHOWN REFER TO THE FBC-2014 FUEL |
| | GAS SECS. 401.8 THRU 402.6.1 AND TABLES 402.4(1) THRU |
| | 402.4(37). |
| | |
| | 11. INDICATE WHAT TABLE YOUR USING FOR SIZING. PER WPB |
| | AMEND TO FBC 107.2.1 |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |