| Plan Review Notes For Permit 16081262 |
| Permit Number |
16081262 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2016-09-28 10:22:22 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. IF THIS PERMIT IS ONLY FOR GARAGE PLEASE REMOVE ANY | | | DETAILS AND RISER DIAGRAMS FROM PLAN SET THAT DO NOT | | | REFLECT THE SCOPE OF WORK FOR THIS PROJECT. WPB AMEND | | | TO FBC 107.2.1 | | | | | | 2. THE KITCHEN SINK DRAIN ON THE SECOND FLOOR SHALL | | | CONNECT TO BUILDING DRAIN DOWN STREAM OF BATHROOM GROUP | | | IT CAN NOT CONNECT BETWEEN BATHROOM FIXTURES. PER FBC | | | PL 912.1 | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. |
|